Graco SHARPE RAZOR A Serie Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Setup
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in
the operating area of the equipment to help protect you from serious injury, including
eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes
but is not limited to:
Protective eyewear
Clothing and respirator as recommended by the fluid and solvent manufacturer
Gloves
Hearing protection
Setup
At least one hose must provide a static
ground to the gun.
Check that your shop air provides
adequate air flow. 12.5 cfm com-
pressor minimum recommended
for best results.
Use a minimum 3/8 in. (10 mm) ID
air hose.
Set shop air pressure regulator
(not supplied) according to paint
manufacturer's recommendation.
See maximum compliant air
pressures on page 2.
Make sure no air restrictions, such as
low-volume cheater-valves, obstruct
the air flow. If an air adjusting valve is
desired, use a SHARPE Air Adjusting
Valve (part nos. 2210, 3310, U04410)
or Digi-tell (part no. U05510).
Install a shutoff valve (not supplied)
downstream of the air regulator to
shut off gun air.
Install an inline air filter (not supplied)
to clean and dry the gun air supply.
1. Shut off the air supply.
2. Connect a clean, dry, filtered air supply
to the air inlet fitting.
4
WARNING
3. Connect a fluid hose to the fluid inlet fitting
3/8-18 npsm (R3/8-19) compound thread.
air inlet
F
. 1
IG
4. Connect the other end of the fluid hose to
a regulated supply line.
5. If this is the first time using the equipment,
flush the gun. See page 7.
fluid inlet
TI11094a
312412B

Publicidad

Tabla de contenido
loading

Tabla de contenido