Oreck ProShield Plus Guía De Usuario página 12

Ocultar thumbs Ver también para ProShield Plus:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

is completely dry, it will return to its original operating settings
and function as normal.
"Dry Mode" Operation
If the power supply detects that the Truman Cell is wet, it shuts
down power to the cell and causes the Collector Cell light to
blink rapidly.
1. While the collector cell light is blinking, press and hold the
power button to initiate "Dry Mode".
2. Next, the following will all happen simultaneously:
• The lights directly above and below the power button
will flash 3 times.
• The unit will switch to medium speed.
• The Collector Cell light will start to blink in a slow
pattern.
4. Once in "Dry Mode"
• The unit will run for 60 minutes and then attempt to
reset the power supply to the Truman Cell.
• If the power supply successfully restarts, the unit will
return to its original speed and run as normal.
• If not successful, it will go through the same process up
to two more times.
• If still not successful after the third try, the cell is likely
damaged or is shorting out due to the presence of a
foreign object; it will return to the original speed and the
Collector Cell light will blink with a rapid blink pattern
indefinitely until the unit is reset.
9