DESCRIPTION

The UNIRIS II line of active infrared barriers generates alarm information upon interruption of 2
beams, while avoiding generation of false alarms from birds, small animals, falling leaves...
The columns are comprised of a transmitter and a receiver column facing each other over the
distance to be protected. This creates an invisible, imperceptible detection zone.
These barriers employ a pulse infrared transmission operating on 4 selectable frequencies
(channels), thereby preventing any risk of interference among them.
The UNIRIS II 50 NH is not fitted out of a heater system (NH = No Heater).
Precautions regarding installation
To install the barriers correctly, it is important to follow certain guidelines.
Do not mount the barrier on an unstable support
(ex: wire mesh, poorly sealed posts, etc.)
Housing plate
Joint
Cell
Infrared cover
Do not install receiver in direct or
reflected sunlight, nor in front of a
highly reflective surface
Infrared module:
cell + control unit
Control unit
Receiver
Verify that no vegetation is blocking
the beams in any season
- 11 -
UNIRIS II 50
ACCESSORIES PROVIDED:
6 mounting screws 4.8x60
-
6 lag shields
-
5° mini
Transmitter