Test For Gas Leaks - Bosch HDI8054 Serie Manual De Instalación

Ocultar thumbs Ver también para HDI8054 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Rigid Pipe Connector Method
If using a flexible connector, return to "Flexible Connector
Method" on previous page.
E
D
B
C
B
A
Gas Flow to Range
Item
Elbow; Connect to regulator here
A
Pipe Nipple
B
Union
C
Elbow
D
Gas Shut Off Valve
E
F
1/2" to 3/4" Gas Pipe
The configuration of the rigid pipe connection will vary
depending on the location of the gas pipe stub.
Complete Gas Connection
1. Connect pipe to range at union. Access the connection
through the access panel behind the drawer.
The gas connection is complete. It is important to test for
gas leaks before proceeding with the remainder of the
installation.
English 15
D
B
F

Test for Gas Leaks

Leak testing is to be conducted by the installer according to
the instructions given in this section.
Note:
Be careful not to apply pressure to warming drawer
element during rigid pipe testing.
1. Turn on gas.
2. Apply a non-corrosive leak detection fluid. Include all
joints and fittings between the shutoff valve and the
range. Include gas fittings and joints in the range if con-
nections may have been disturbed during installation.
3. Inspect for leaks. Bubbles appearing around fit-
tings and connections indicate a leak.
4. If a leak appears, turn off supply line gas shutoff valve
and tighten connections.
5. Retest for leaks. Turn gas back on at supply line shutoff
valve and reapply leak detection fluid.
6. When no bubbles appear, test is complete. Wipe off all
detection fluid residue.
.
9 WARNING
Never check for gas leaks with a flame.
Do not continue to the next step until all leaks are
eliminated.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hdip054 serieHgi8054 serieHgip054 serie

Tabla de contenido