Input 2 alarm delay
Input 2 polarity:
Normally open – The input is activated on closing the contact
Normally closed – The input is activated on opening the contact
Inact. with door open (time)
Cold room light timing
AUXILIARY RELAY control
Aux. relay configuration:
Disabled
Activated by key
Activated byInput
2nd defrost
Pump down control
Defrost 2 duration
Defrost 2 final temp.
Defrost 2 sensor:
Disabled
Pump down duration
Pump down On delay
GENERAL STATUS
Access password (to parameters and set point)
Password to Set Point
Initial parameters (configures the default values and exits programming)
Registry interval
Communication address
Parameters transfer:
Disabled
Send – The unit sends the parameters to the programming key
Receive – The unit receives the parameters from the programming key
Connected sensors:
Sensor 1
Sensor 1 and 2
Sensors to be displayed
Display mode:
One sensor and clock One sensor and text
Display unit
Decimal point
Description
Description
Equal state equipment
Equal compressor state
Probe 2
Probe 3
Description
Sensor 1 and 3 Sensor 1, 2 and 3
Sensor, clock and text
Units
Min
Def
Max.
(min.)
0
0
255
NC
(min.)
0
0
255
(min.)
0
0
255
Units
Min
Def
Max.
Dis.
(min.)
0
30
255
(ºC/ºF)
–40.0
8.0
99.9
Dis.
(Sec.)
1
30
1800
(Sec.)
0
60
Units
Min
Def
Max.
00
00
No
No
(min.)
0
15
0
1
255
Dis.
S1
1
1
S1 and
r.
ºC
ºC
Yes
60
99
60
3
ºF