TROUBLESHOOTING
Problem
Dispensing nozzle not dispensing Battery charge low
ELECTRICAL DIAGRAM
+
POSITIVE LEAD (RED)
CIRCUIT BREAKER
12V
15 A
D/C
NEGATIVE LEAD (BLACK)
−
100−Tb/200−Tb DM20016 (7−2012)
Cause
Battery no longer holds charge
Circuit breaker tripped
Toggle switch in OFF position
TOGGLE
SWITCH
OPERATION EN
Remedy
Return machine to charger and
recharge battery
Replace battery
Reset Circuit Breaker
Turn toggle ON/OFF switch to
the ON position.
PRESSURE
SWITCH
POS
NEG
BATTERY
METER
PUMP
MOTOR
12 VDC
14 AMP
11