Kenmore 110.70012 Serie Manual De Uso página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate installations
are available for purchase. For further information, please call
1-800-4-MY-HOME
(1-800-469-4663).
®
Over-the-Top Installation:
Part Number 26-49900
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5" (127 mm) mismatch
Part Number 26-49908 - 5" (127 mm) to 18" (457 mm)
mismatch
Part Number 26-49904 - 18" (457 mm) to 29" (737 mm)
mismatch
Part Number 26-49905 - 29" (737 mm) to 50" (1270 mm)
mismatch
10
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
The Vent System Chart provides venting requirements that will
help achieve best drying performance.
Vent System Chart
Type
Number of
of vent
90° turns
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
Determine vent length
Select route that will provide straightest and most direct path
outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Box/Louvered
Angled
hoods
hoods
58 ft. (17.7 m)
64 ft. (20 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4 m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

110.70172 serie

Tabla de contenido