Assembly; Wall Mounting; Conductivity Probe Connection - Aqua DGTEC CD Manual De Instrucciones

Ocultar thumbs Ver también para DGTEC CD:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 104
dGdoser Model
Programmable digital peristaltic pump

2.3 ASSEMBLY

We always recommend wearing protective masks, gloves, goggles and any other PPE during all
installation steps and when handling chemical products.
Proceed as follows to secure the pump to the wall:
Fix the bracket to the wall using the plugs and screws supplied.
Place the pump on the bracket.
Ensure the fixing is stable.
It is also recommended to install the pump in a dry environment, away from heat sources and
exhaust vapour.
2.3.1

CONDUCTIVITY PROBE CONNECTION

The provided conductivity probe is a 2-wire conductivity meter type. Upon request, it is possible to receive a 4-wire
temperature-compensated probe. The codes set out in Tab. 1 do not consider this option.
Fig. 3 Conductivity Probe
To carry out correct installation of the conductivity probe onto the dishwasher, verify the points detailed hereunder:
install the probe in the washing tank;
the probe electrodes must be at least 4 centimetres below the maximum filling level;
install the probe close to the washing pump filter;
Do not install the probe close to edges, electrical resistance, detergent input and at the bottom
of the tank.
Should the dishwasher not be predisposed to assemble the conductivity probe, make
a 23 mm hole in the washing tank wall.
ADSP7000634

WALL MOUNTING

Fig. 4 - Conductivity card
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
30/06/2014
ENGLISH
40/206

Publicidad

Tabla de contenido
loading

Tabla de contenido