dGdoser Model
Programmable digital peristaltic pump
the temperature value (°C) set manually or read by the PT100 temperature probe from 0.0 to 99.9°C: if the
automatic temperature has been set and the temperature probe is not connected, the display will show "t -
- ".
From the temperature value, always using the F key, you go back to the first entry, which will be preceded by the
label "St.d" (dosing status) if the switch is ON.
From any entry of the Initial Menu you can go to the:
Programming Menu by pressing Enter for 3 seconds;
User Menu by pressing the F key for 3 seconds;
User Menu
The User Menu allows you to set fundamental parameters for pump dosing and set-point conductivity.
You can browse through the User Menu with the F key and display:
AdE: allows to prime the pump without using the switch. You can start or stop the priming with the Enter
key. The display shows a flashing "AdE" and the pump starts running at top speed.
SEt: allows you to set the set-point value from 0 to 100 units;
The Set-point parameter can be changeable only if it has been enabled from the Settings Menu, or if:
 OnL (on-line change) enabled;
From the User Menu you can go back to the Initial Menu by pressing the F key for 3 seconds.
Should there be one or several active alarms, every page of the Initial Menu and User Menu will be
alternated to the entry that reports the signal with top priority. (see Alarm section).
Programming Menu
The Programming Menu allows to set all of the pump's operating parameters and can be accessed only by entering
the password.
You can enter the Programming Menu only from the Initial Menu: after pressing Enter for 3 seconds, the display
shows "PAS", the LED turns orange and is steady. Then press Enter again and on the password selection menu
the first digit of "000" starts flashing. With the ▲ and ▼ keys you can increase/decrease the value displayed, with
Enter you can scroll and select the desired digit. After setting the correct password, press Enter again for 3
seconds.

3.2 QUICK START-UP

This section features the steps to carry out to use the pump straight away. For further details on operation, refer to
section 3.3 "Advanced Programming".
The fundamental parameter to set for pump operation is:
From the User Menu you can proceed quickly with the steps below:
Prime the pump;
Select the Setpoint;
Here below are the pump default parameters:
Disabled temperature correction;
On-line Change of Set-point from enabled User Menu;
USER MENU
ADSP7000634
Conductivity Set Point
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
30/06/2014
ENGLISH