DITEC PASM24T Guia Del Usuario página 15

Sensor de movimiento autovigilado para puertas automáticas de ayuda
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

During an adjustment session all parameters may be reset to their factory values in the following way :
PARAMETERS
OPERATIONS
FACTORY
Press the SETUP key (19), then press the NUMBER key 9.
VALUES
All the parameters (except the access code) are reset to the factory values.
FACTORY VALUES :
If you do not have a remote control, you can only adjust the sensitivity parameter, by means of the push buttons + and - .
SENSITIVITY
CONFIGURATION
WITH PUSH
BUTTONS
The factory default values (except the factory value of the access code) may be restored by pressing the two push buttons together for
at least two seconds.
LED SIGNAL
SYMPTOM
TROUBLE-
The door will not open.
SHOOTING
Red LED ON.
The door will not close.
Red LED OFF
The door will not close.
Red LED ON. No apparent motion.
The door will not close.
Red LED flashes slowly
(slower than the RC flashings)
The door opens and closes constantly.
It rains and the sensor detects for no
apparent reason.
In airlock vestibules, the sensor sees the
opposite door.
In airlock vestibules, the sensor sees the
movement of the door leaves, despite of
an increased immunity.
In metallic environments, the sensor
detects objects outside its detection field.
The sensor will not unlock when access
code is entered.
The sensor does not respond to the
remote control.
Parameter
Sensitivity
Hold time
Detection mode
Immunity
Mounting height
Door control
The LED flashes for a few seconds after the power-on, and flashes during
the configuration with the remote control.
The LED lights up when the sensor detects motion.
PROBABLE CAUSE
On-Off switch at door control in wrong position
or faulty.
Incompatibility between the sensor output and
the activation input.
The sensor power is off.
Incompatibility between the sensor output and
the activation input.
The door control is set on ''door permanently
open''.
The power supply is too low
or
short interruptions on the power supply
The sensor "sees" the door moving.
When closing the door creates vibrations
picked up by the sensor.
The sensor detects the motion of the rain
drops.
Improper access code being entered.
Batteries in remote control weak
or installed improperly.
Remote control badly pointed.
Factory Values Table
Values
0 - 9
0 - 9
1 - 5
1 - 9
1 - 2
1 - 2
+ : press to increase the sensitivity by one unit
- : press to decrease the sensitivity by one unit
Factory setting
7
0
2
2
1
1
CORRECTIVE ACTION
Check to insure On-Off switch for door is in
the ON or AUTOMATIC position.
See the technical specification.
Check the wiring and the power supply.
See the technical specification.
Change the door control setting on each
sensor connected to the door operator.
Check the power supply.
Cut and restore the power supply.
If the door stays open, replace the sensor.
Increase the tilt angle and/or reduce the
sensitivity and/or increase the immunity.
Make sure that the sensor is correctly fixed.
Switch to unidirectional mode.
Increase immunity and/or reduce sensitivity.
Use the ERA accessory.
Switch to unidirectional mode (without MTF)
and increase the immunity.
Increase immunity.
Make sure that the antenna for the narrow
sensing field is used.
Increase immunity.
Cut and restore power supply. No access
code is required to unlock during the first
minute after powering. Press "unlock", then
"lock" and introduce a new access code.
Check the batteries insertion.
Change the batteries.
Point remote control towards the sensor.
7/8

Publicidad

Tabla de contenido
loading

Tabla de contenido