Technical Data; Base Plate Position; Preliminary Checks - Bauer CROSS5 Serie Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
1.

TECHNICAL DATA

Power supply
230 V~ / 50 Hz
Absorption
Thrust
Condenser
Max run
Door speed
Max door weight
Service class
3 - FREQUENT
Min number of
consecutive cycles
Intermittence
Temperature
Degree of protection
Control panel
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
2.1 Standard installation references (fig. 1)
[1]
Radio
[2]
Flashing light
[3]
Key selector
[4]
Geared motor + control panel
[5]
Photocells
[6]
Rubber edge - sensitive edge
[7]
Opening and closing stop
[8]
Connect power supply to an type-approved omnipole
switch with a contact opening gap of no less that 3 mm
(not supplied by us)
Connection to the grid is made with independent channels
and separated from the connections to the control and
safety devices.
2.2 Geared motor references (fig. 3)
[9]
Motor
[10] Casing
[11] Manual release
[12] Control panel
[13] Limit-switch spring
[14] Pinion
[15] Internal photocell
[16] Courtesy light (optional)
[17]
BATK7 battery kit (optional,
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm).

3.1 Preliminary checks

Check the stability of the wing (derailing and lateral falls) and
the sliding wheels and that the upper guides do not cause any
friction.
The sliding guide must be securely fixed to the ground for the
full length within the doorway and must have no irregularities
that could hinder the movement of the gate.
The opening and closing stops must be fitted.
CROSS5E
CROSS5EH
230 V~ / 50-60 Hz
1,5 A
1,2 A
500 N
400 N
12,5 µF
20 m
20 m
0,18 m/s
0,09 - 0,21 m/s
400 kg
450 kg
4 - INTENSIVE
20
50
S2 = 15 min
S2 = 30 min
S3 = 25%
S3 = 50%
-20 °C/+55 °C
-20 °C/+55 °C
IP24D
IP24D
E1
73RM
only CROSS5EH-7EH)
CROSS7E
230 V~ / 50 Hz
2 A
700 N
-
16 µF
20 m
0,18 m/s
600 kg
4 - INTENSIVE
30
S2 = 20 min
S3 = 50%
-20 °C/+55 °C
IP24D
E1A
Note: make sure that the gate can not exit the sliding guides
and fall.
If the gate has slits, make sure they are covered to prevent
shearing points.
Safety device should be installed at the end of the wing to reduce
the collision force.

3.2 Base plate position

-
First, insert the screws into the base plate blocking them
with a low nut [P], then, fold the tang to avoid displace-
ment.
-
Take out the preformed wall anchors with a downward
movement and with the help of a hammer to ensure proper
anchorage to the concrete.
CROSS7E
CROSS7EH
CROSS8E
P
CROSS5E
CROSS5EH
11
CROSS7EH
CROSS8E
230 V~ / 50-60 Hz
230 V~ / 50 Hz
1,5 A
600 N
800 N
-
22 µF
20 m
0,12 ÷ 0,20 m/s
0,18 m/s
600 kg
800 kg
4 - INTENSIVE
4 - INTENSIVE
50
S2 = 30 min
S2 = 20 min
S3 = 50%
S3 = 50%
-20 °C/+55 °C
-20 °C/+55 °C
IP24D
IP24D
73RG
CROSS5-7-8 - IP1747
GB
3 A
20 m
30
E1A

Publicidad

Tabla de contenido
loading

Tabla de contenido