Electrical Connections - Bauer CROSS5 Serie Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
4.

ELECTRICAL CONNECTIONS

GB
The electrical connections and starting are illustrated in the
installation manual of the control panel.
230 V~ cables (power supply, flashing light and external courtesy
light) are to be positioned on the right of the electric control
panel.
24 V= cables (safeties, controls and external antenna) are to be
positioned on the left of the electric control panel.
ATTENTION: Connect the yellow-green ground cable to the
clamp already connected to the motor, as it is shown in the
figure.
yellow-green
5.
PHOTOCELLS INSTALLATION (fig. 4)
Additional photocells may be installed inside the gearmotor for
the protection of both opening and closing movement.
Fit a receiver (RX) or a transmitter (TX) on the [U] brackets
provided.
Installation of the photocells must be carried out in observance
of the standards EN12453 and EN12445.
Attention: the photocell receiver (RX) and transmitter (TX) may
also be installed at two different heights, the maximum permis-
sible difference in height being 300 mm.
6. LUXK7 INSTALLATION (fig. 5)
The courtesy lamp can be mounted inside the gear motor. For
mounting and connection, carry out the operations shown in
the figure.
ATTENTION: Connect the yellow-green ground cable to the
clamp already connected to the motor, as it is shown in the
figure.
The courtesy lamp can be enabled or disabled by means of
a GOL4 radio remote control and by storing the CH3 function
(see instructions).
All rights reserved
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
CROSS5-7-8 - IP1747
7. BATK7 INSTALLATION (only CROSS5EH-7EH)
The BATK7 battery kit permits to operate the gate even in case
of mains power failure.
Note: when not in use, batteries are kept charged by means of
the control circuit.
Fit the batteries inside the geared motor and secure by means
of the appropriate support brackets (see BATK7 instruction
manual).
8. MAINTENANCE PROGRAM (every 6 months)
Disconnect the power supply and release the gearmotor (see
RELEASE/BLOCK operations):
-
Visually check that the gate, the fixing brackets and existing
structure have suitable mechanical strength and are in
good condition.
-
Check the gate-gearmotor alignment, the distance (2-3
mm) between the throat of the pinion, the crest of the rack.
-
Clean the wheel's sliding guide, the rack and pinion of the
gear motor and slightly lubricate the rack and pinion of the
gearmotor. Manually check that the gate slides evenly and
without friction.
-
Check the capacity value of the condenser.
Connect the power supply and block the gearmotor (see RE-
LEASE/BLOCK operations):
-
Check that the limit switches are working correctly (the
gate should stop 20 mm before the stop).
-
Check the power adjustment.
-
Check that all control and safety functions are working
correctly.
ATTENTION: For spare parts, see the spares price list.
14