Tabla de contenido

Publicidad

64
AVENTICS | AV03/05 with IO-Link | R412018145–BAL–001–AC
Conversion of the Valve System
1
6
2
AES-
IOLINK-
24DO
AV03-B
IO-Link
P
Fig. 9:
Creating sections with three pneumatic supply plates
1 IO-Link interface
2 IO-Link interface multipole board
6 Pneumatic supply plate
10 Base plate, 2x
11 Base plate, 3x
14 Multipole board, 4x
13 Multipole board, 3x
15 Bridge card
18 Valve
10.4.1

Sections

The valve zone of a valve system can consist of multiple sections. A section always starts with a
supply plate that marks the beginning of a new pressure zone. The first section is always a minimum
of 6 valve positions long.
11
11
18
11 13
MIN
S1
The valve system in Fig. 9 consists of three sections:
Table 12:
Example valve system, consisting of three sections
Section
Section 1
Minimal con-
figuration
Extension
Section 2
Extension
Section 3
Extension
18
6
15
14
10
P
S2
MIN
Minimal configuration
S1
Section 1, multipole expansion
S2
Section 2, multipole expansion with supply plate
S3
Section 3, multipole expansion with supply plate
IO-Link Power and signal supply
P
Pressure supply
Components
Pneumatic supply plate (6)
Two base plates, 3x (11)
IO-Link interface multipole board (2)
6 valves (18)
Base plate, 3x (11)
Multipole board, 3x (13)
3 valves (18)
Pneumatic supply plate (6)
Bridge card (15)
Four base plates, 2x (10)
Two multipole plates, 4x (14)
8 valves (18)
Pneumatic supply plate (6)
Bridge card (15)
Two base plates, 2x (10), and one base plate, 3x (11)
Multipole board, 4x (14) and multipole board, 3x (13)
7 valves (18)
14
18
6 15
10
P
S3
14
11
13
18

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Av03/05 with io-linkAv03/05 avec io-linkAv03/05 con io-linkAv03/05 med io-link

Tabla de contenido