05-350 / 05-338
3.6. Function tables
1. 05-350 2-channel receiver, modular
The switching function is defined with the 'mode' rotary switch
mode settings
Location
mode execution
of the
control
Top
M1
2-key
Bottom
Top left
Top right
M2
4-key
Bottom left
Bottom left
M3
1-key
M4
1-key
M5
1-key
M6
1-key
M7
1-key
MA
1-key
MB
1-key
* see table with time functions
EN
Time of
Function?
control*
Short (<400ms) Dim to last value
Long (>400ms) Increase from current value to max. value
Short (<400ms) Dimmer off
Long (>400ms) Decrease from current value to min. value
Dim to last value
Increase from current value to max. value
Dimmer off
Decrease from current value to min. value
Recall preset
Short (<1,6s)
Recall licht scene
long (>3s)
Save new light scene
T2*
Dim to last value
T2*
Dimmer off
Dimmer off, 3min decay
Short
Dimmer On/Dimmer Off /Dimmer On/etc
Increase to max. value – Decrease to min. value
Long
Remain 2s at min. value
Short
Dim to last value/Dimmer Off / etc.
Increase to max. value – Decrease to min. value
Long
Remain 2s at min. value
operating
switch-
time*
off time*
During
T
actuation
45