Descargar Imprimir esta página

Grohe TALIA 24 667 Manual Del Usuario página 4

Ocultar thumbs Ver también para TALIA 24 667:

Publicidad

Idiomas disponibles

Idiomas disponibles

Application
Operation is possible in conjunction with:
• Pressurized storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement water
heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
Notes:
- Installation of backflow protection must comply with local codes
and regulations.
- Major pressure differences between cold and hot water supply
should be avoided.
Installation
Refer to the dimensional drawing on fold-out page I.
Flush piping system prior and after installation of faucet
thoroughly!
Side valves
• Valve with a groove on the top edge of the cartridge (A1) and in
addition marked with blue tape should be mounted on the right
(cold water) side, see fold-out page II, fig. [1].
• Valve without a groove on the top edge of the cartridge (A1) and
in addition marked with red tape should be mounted on the left
(hot water) side.
1. Screw the mounting set (B) to the bottom of the thread of the side
valve (A). Make sure that the rubber washer (B1) is on the top of
the fiber washer (B2).
2. Insert the side valve (A) through the basin hole from below.
3. Slide on seals (C) and screw on nut (D). Make sure that the fiber
washer (C1) is on the top of the rubber washer (C2).
4. With 32mm open-ended spanner fasten the side valve (A). The
distance between the top of the headpart and the basin must
be 1 25/32", see fig. [2].
5. Screw the escutcheon (D1) down to the nut (D), see fig. [1].
Mount lever (18 077) not included in the scope of delivery, see
fig. [3].
- Push ring (A2) onto headpart (A1).
- Push on lever.
Install lever (18 085) not included in the scope of delivery.
- Push on lever complete and screw cap (F) onto
headpart (A1).
Vacuum breaker
1. Insert the vacuum breaker body with seal (G) and nut (G1)
through the basin hole from below, see fig. [4].
2. Slide on seal (G2) with ring (H) and screw on nut (I).The distance
from the top of the body to the bottom of the ring must be 2 3/16",
see fig. [6].
3. Secure vacuum breaker body to the basin by tightening
nut (G1), see fig. [4].
4. Slide on tube (J) and cover (K), see fig. [5].
5. Tighten the connection tee (L) to the vacuum breaker body with
connection nut (M).
1
English
Diverter
1. Insert diverter body with nut (N) and seals (O), (O1 or O2)
2. Slide on seal (O3 or O4) and screw on nut (P) until it is at the
3. Secure diverter body to the basin by tightening nut (N) using
4. Screw on escutcheon (Q), see fold-out page III, fig. [8].
5. Press on snap insert (R) and secure with screw (R1).
6. Push on handle (S).
13.7 L/min or 3.6 gpm / 45psi
Verticle spray, see fig. [9].
1. Insert body with seals (T) from below.
7.25 psi
2. Slide on seals (T1) and secure with nut (U) using a 22mm open-
14.5 - 72.5 psi
3. Jet-height can be decreased by turning the nozzle (V) to the left,
145 psi
232 psi
4. Screw on spray face plate (W).
176 °F
Fit pop-up drain (28 957), see fold-out page I, ensure that flange
cold - Right hand
of pop-up drain is sealed.
hot - Left hand
Connect wideset bidet, see figs. [10] and [11].
1. For this purpose the supply pipes must be installed on to the
2. The cold water supply should be connected on the right, the hot
3. Connect both side valves to the connection tee via the flexible
4. Connect the flexible hose from the vacuum breaker to the
5. Connect the verticle spray to the bottom of the diverter.
Open cold and hot water supply and check connections for
leakage!
Maintenance
Inspect and clean all parts, replace as necessary and grease with
special grease (Prod. no. 18 012).
Shut off cold and hot water supply!
I. Replacing the headpart, see fig. [12].
1. Remove lever
2. Unscrew headpart (A1) using a 17mm socket wrench.
3. Change complete ceramic cartridge (A1) or O-ring (A3).
Observe the correct installation position!
II.Vacuum breaker, see fig. [13].
1. Pull off cover (K) and tube (J).
2. Remove circlip (X), pull out and replace double-ball vacuum
3. Loosen nut using a 21mm open-ended spanner and replace
III.Vertical spray, see fig. [14].
Unscrew and clean spray face plate (W) and nozzle (V).
Assemble in reverse order.
Replacement parts, see fold-out page I ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
through the basin hole from below, see fig. [7].
same height as the top of the diverter body (P1).
a 36mm open-ended spanner.
ended spanner.
turning to the right increases jet-height.
angle stops (or other supply points).
water supply on the left side.
hoses.
diverter.
Lever (18 077):
- Pull off lever.
- Pull off ring (A2).
Lever (18 085):
- Unscrew cap (F) and pull off lever complete.
Observe the different replacement part numbers of the
headparts, see fold-out page I.
breaker (Z).
check valve (08 565), see fold-out page I.

Publicidad

loading