CONTROLS AND OPERATION

1.
Plug cord into wall receptacle. Your humidifier is now ready for use. The
humidifier should not be near any heat registers.
2.
Place the unit at least FOUR inches away from any walls. Unrestricted airflow
into the unit will result in the best efficiency and performance.
accessed, it displays ambient and set humidity, fan speed and status of the unit.

FAN SPEED

5.
Adjust fan speed by pressing the small fan icon to lower speed, or
pressing the large fan icon to increase fan speed. The display will
show F1 through F9 proceeding from low to high speed.
NOTE: When excessive condensation exists, a lower speed setting is recommended.

HUMIDITY CONTROL

NOTE: The EA12 series has an adjustable humidistat that cycles the humidifier on
and off as required to maintain the selected setting.
6. At initial startup the ambient humidity of the room will be displayed.
Increase the humidity setting in 5% increments by pressing the large droplet icon.
Decrease the humidity level by pressing the small droplet icon.
7. At 65% set point, the unit will operate continuously.
OTHER INDICATIONS
8. When the unit runs out of water the control will display a flashing "F".
When the unit is completely out of water, the motor will shut off.
9. This humidifier has a check filter reminder timed to appear after 720
hours of operation. When the Check Filter (CF) message is
displayed, disconnect the power cord and check the condition of the
filter. The CF function is reset after plugging the unit back in.
CONTROL LOCK OUT
To avoid unwanted tampering with the humidifier settings the controls can be locked.
Activation Procedure
10. After the humidifier functions have been set up, press and hold the
power button down for 5 seconds. The display will show "CL" for 5
seconds; release the power button and the control will resume the
display of the room humidity.
The humidifier will continue to function with the locked in settings. If buttons are
operated while "CL" is active, the "CL" is displayed and settings are unaffected.
Deactivation Procedure
11. To deactivate the "CL" function simply press and hold the power button for 5
seconds. "CL" will flash and then resume the display of room humidity
6
3. The digital touch
screen panel allows you
to control the fan speed
and humidity level by
simply tapping the
appropriate switch on
the front of the
panel.
4. A digital display
provides information on
the status of the unit.
Depending on which
function is being
.