Wired keyswitch
A
7 s
B
ParamEtEr sEttiNG
+
Potentiometers: to modify the automatic closing time and the motor run time.
TCA:
TCA
Automatic closure time
-
TW:
+
Motor run time
DIP switch: to select the operating mode for the motor and its additional devices.
TW
DIP 1:
-
Automatic closure
DIP 8
DIP 7
DIP 2:
DIP 6
Operation of the
photoelectric cells
DIP 5
DIP 4
DIP 3
DIP 2
DIP 1
ON
OFF
DIP 3:
Blocking impulses
DIP 4:
3 Step/4 Step
DIP 5
DIP 6
DIP 7
Pedestrian opening
Copyright © 2008 Somfy SAS. All rights reserved.
A
B
Between 0 and 90
seconds
Between 0 and 120
seconds
ON: Activates automatic
closure
off: deactivates
automatic closure
ON: In closing mode only.
off: in opening and
closing mode.
ON: In opening mode only
off: None
ON: Activates the 3 step
logic.
off: activates the 4
step logic.
DIP 5 and 6 are not used and have no effect on the operation of the motor
and its additional devices.
ON: Activates the
pedestrian opening.
off: deactivates the
pedestrian opening.
Setting the time delay for automatic closing
(if DIP1 is ON).
The motor run time should be slightly longer than
the actual closing time of the gate.
The gate closes automatically after the
programmed time delay (TCA).
In closing mode, the gate stops then reverses its
movement.
In opening mode, cells are inactive.
in closing mode, the gate stops and reverses
its movement once the cells are no longer
obstructed.
in opening mode, the gate stops then
continues its movement once the cells are no
longer obstructed.
Impulses during opening have no effect.
3 STEP = operation in semi-automatic mode
(see "User's manual" pg. 2).
4 stEP = operation in sequential mode
(see "User's manual" pg. 2).
Pressing the remote control briefly partially opens
the gate and pressing and holding the remote
control fully opens the gate.
Fixed opening time: 7 seconds.
Elixo 500 230 V
9