Technical parameters

Input
Analog inputs:
Number of inputs:
Galv. separation from inner
circuits:
Diagnostic:
Common terminal:
Converter resolution:
Input resistance
- for voltage ranges:
- for current ranges:
Types of inputs / measuring
ranges*:
temperature: input at ext. temperature sensor TC,
Digital inputs:
Input voltage:
Galv. separation from internal
circuits:
Common lead:
Outputs
Analog:
Voltage analog. output / max.
Current:
Uref reference voltage
outputs
Voltage / Current Uref:
Output overload indication:
SSR (Electronic Relay):
Switching voltage:
Switching capacity:
Peak current:
Output indication:
Relay 6A:
Switching voltage:
Switching capacity:
Relay outputs separated from
from all internal circuits:
Minimum switching load:
Mechanical life:
Electrical life AC1:
Output indication:
Communication
Installation BUS:
Status indication unit:
Power supply
Voltage of BUS / tolerance /
rated current:
Supply voltage of power
section (relay) / tolerance /
nominal current:
Dissipated power:
Connection
Terminal:
* Selectable for each input individually by confi guration in the user program iDM3.
** The FA3-612M/Pt version is available for these sensors.
TECHNICAL SUPPORT | E-mail: support@inels.com | Mobil: +420 778 427 366 | Tel.: +420 573 514 276, +420 573 514 211 | Fax: +420 573 514 227 | www.inels.com
Made in Czech Republic
3x voltage, current or temperature input
3
No
indication red LED OVERRANGE
(exceeding the range, interruption of a sensor or
overload of Uref output)
GND
14 bits
approx. 150 kΩ
100 Ω
Voltage (U): 0 ÷ +10 V (U) ; 0 ÷ +2 V (U)
Current (I) : 0 ÷ +20 mA (I) ; ÷ +20 mA (I)
TZ, Ni1000**, Pt1000**, Pt100** see accessories /
according to used sensor from -30°C to 250°C
3x switching or expansion, positive logic (SINK)
20 - 240 V AC (50 - 60 Hz) / DC
Yes
GO COM3
4x (A_OUT1 - A_OUT4)
4x 0(1) - 10 V / 10 mA
10 V DC / 100 mA
red LED OVERLOAD
4x (VALVE1 - VALVE2)
20 - 240 V AC
480 VA
20 A, t ≤ 16 ms
yellow LED
4x (FAN1-FAN3, RE)
250 V AC, 24 V DC
1500 VA / AC1; 300 VA / AC15; 180 W/DC, AC3
reinforced Insulation
(Cat. II surges by EN 60664-1)
500 mW (12 V / 10 mA)
10x10
6
4
6x10
yellow LED
BUS
green LED RUN
27 V DC, -20 / +10 %, 5 mA
AC 230V (50 Hz), -15 / +10 %, 20 mA
max. 1 W
max. 2.5 mm
2
/ 1.5 mm
2
with sleeve
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech republic | e-mail: elko@elkoep.com
Operating conditions
Operating temperature:
Storing temperature:
Protection degree:
Overvoltage category:
Pollution degree:
Operating position:
Installation:
Design:
Dimensions and weight
Dimensions:
Weight:

Indication LED

Flashing interval of the respective LED when the maximum number of contacts is exceeded when
the relay is switched on (FAN, RE):
Flashing interval of the respective LED when the max. Number of contacts is exceeded when the
relay is switched off (FAN, RE):
Warning
Before the device is installed and operated, read this instruction manual carefully and with full
understanding and Installation Guide System iNELS3. The instruction manual is designated for
mounting the device and for the user of such device. It has to be attached to electro-installation
documentation. The instruction manual can be also found on a web site www.inels.com. Attention,
danger of injury by electrical current! Mounting and connection can be done only by a professional
with an adequate electrical qualifi cation, and all has to be done while observing valid regulations.
Do not touch parts of the device that are energized. Danger of life-threat! While mounting,
servicing, executing any changes, and repairing it is essential to observe safety regulations, norms,
directives and special regulations for working with electrical equipment. Before you start working
with the device, it is essential to have all wires, connected parts, and terminals de-energized. This
instruction manual contains only general directions which need to be applied in a particular
installation. In the course of inspections and maintenance, always check (while de-energized) if
terminals are tightened.
-20 .. +55°C
-30 .. +70°C
IP20 device, IP40 mounting in the switchboard
II.
2
any
switchboard on DIN rail EN 60715
6-MODUL
90 x 105 x 65 mm
307 g
2/2