Programming; Settings Table - BRÖTJE CISP C Montaje / Ajuste

Módulo de señal de tensión/ relé
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
6.

Programming

6.1

Settings table

Table 2: Setting the parameters
Function
Configuration
Relay output K2
Default | Message output | Alarm output | operation mes-
sage | External transformer | Heating circuit pump HC2 |
circulation pump | Gate veil function | Pump hydraulic
bypass | feed pump Q8 | Basic function K2 | TWW-charging |
threshold analoguous signal RelCl | Exhaust gas flap | coll-
ector pump | fan switch-off
Relay output 1 RelCl
Default | Message output | Alarm output | operation mes-
sage | External transformer | Heating circuit pump HC2 |
circulation pump | Gate veil function | Pump hydraulic
bypass | feed pump Q8 | Basic function K2 | TWW-charging |
threshold analogue signal RelCl | Exhaust gas flap | collec-
tor pump | fan switch-off
Relay output 2 RelCl
Default | Message output | Alarm output | operation mes-
sage | External transformer | Heating circuit pump HC2 |
circulation pump | Gate veil function | Pump hydraulic
bypass | feed pump Q8 | Basic function K2 | TWW-charging |
threshold analoguous signal RelCl | Exhaust gas flap | coll-
ector pump | fan switch-off
Relay output 3 RelCl
Default | Message output | Alarm output | operation mes-
sage | External transformer | Heating circuit pump HC2 |
circulation pump | Gate veil function | Pump hydraulic
bypass | feed pump Q8 | Basic function K2 | TWW-charging |
threshold analoguous signal RelCl | Exhaust gas flap | coll-
ector pump | fan switch-off
Function input RelCl
No | Modem function | Modem function inverse | Gate veil
function | Nominal value specification | Power specification
| Sensor hydraulic bypass | Feed-back exhaust gas flap |
generator lock | generator lock inverse | Generator lock
sensor
Ext. Flow nominal value maximum
Ext. Power specification threshold
1. E = End user; I =Commissioning; F = Specialist
0-10 V / Relay module CISP C
• Only the most important parameters for the module CISP C are
listed in the table!
• In order to get to the setting levels: End User (E), Start-up (l)
and Specialist (F), press button OK.; After this, press for appro-
ximately 3 s the Information button, select the reqired level
with the rotating knob and acknowledge with the button OK.
Detailed information for programming of the integrated system
controller LMU 74 and setting tables with programmable parame-
ters are contained int he installation manual of the boiler.
Programming
Setting
Prog.-
Standard
1
No.
value
level
5920
I
Fan shutdown
rsp. Basic
function K2
5922
F
Alarm output
5923
F
Status output
5924
F
Default
5973
I
Preselected
setpoint
resp. Prese-
lected output
5975
F
100 °C
5976
F
5 %
GB
Modified
value
21

Publicidad

Tabla de contenido
loading

Productos relacionados para BRÖTJE CISP C

Tabla de contenido