Scope of delivery for QA..Z, QAe..Z
a. Ordered measuring instrument
b. 8 hexagon screws and nuts
QA..Z, mechanical index:
c. 2 plugs for pulse generators
QAe..Z, electronic index:
c. 1 plug for pulse generator
Plug for pulse generator
Available as an option for QAe...Z:
d. M-BUS/L-BUS
3.2 Storage
Store the device in a dry and dust-free location.
Avoid constant direct sunlight.
Store the device in its original packaging.
3.3 Requirements to be met before installation
Remove sealing caps and foils in full. There must be no residue left on
the flow body.
Check the meter and accessories for signs of transport damage.
Check that the turbine moves easily by generating a gentle air current.
Ensure that you have all the tools you require available.
Check that the accessories are complete.
Seals which are suitable for your operating medium.
Please also check whether you must comply with other standards, e.g.
DIN EN 1591, Parts 1 – 4.
73025026a
© Elster GmbH | All rights reserved. Subject to modification
Fig. 4 | Scope of delivery for QA..Z, QAe..Z
Honeywell
17