PROBLEMS AND SOLUTIONS POOLWATCH BASIC pH /Cl INORGANIC
PROBLEMS
pH level above the programmed
value (if enhancer is used)
pH level below the programmed
value (if reducer is used)
Chlorine level over the programmed
value.
Chlorine level below the
programmed value.
Led indicator of the pH or Cl pump
dispenser connector (activated) but
the pump dispenser is not working.
The engineered valve does not open
and the relay is on.
The physicochemical analysis of the
pool water, that is the pH and Cl
level do not correspond to the PW
Basic reading. (There is too much
difference)
The alarm of wealth is activated,
d
there appears
iscontinuously"
ERROR N.02 LACK FLOW ".
It does not circulate water for the
hydraulic circuit of the equipment.
CAUSES
You selected a % of the dis-penser pump
higher than the suitable one.
You selected a % of the dis-penser pump
higher than the suitable one.
The chlorine dispenser pump has a higher
percentage than the suitable one.
The chlorine dispenser pump has a lower
percentage than the suitable one.
a)
The connection bridge of the connectors 1-4
and 2-5 of the grid connectors has not been
done.
b)
Filtering stopped
c)
Delay activated
Improper connection
a) Dirty cartridge filter (see pages 5-6 point n 5)
b) Dirty probe o chlorine sensor (cell)
c) Expired electrodes.
d) Unproper photometer reading.
e) High water temperature > 28ºC
a)
There is no water running through the
analysis chamber
b)
Faulty connection to the flow detector
a)
Soiling of the filter mesh.
b)
Presence of particles in the
analysis chamber.
c)
Closed the valves of entry or exit
14
Reduce the % adjusting it to the pool
characteristics.
Reduce the % adjusting it to the pool
characteristics.
Reduce the percentage adjusting it to the pool
characteristics.
Increase the percentage adjusting it to the
pool characteristics.
a)
Do the connection to the connectors 1-4 and
2-5 of the grid connector.
b)
If the filtering is in automatic mode, wait until
it starts working according to the selected
time, or switch the filtering on manually.
c)
Switch off the delay pressing the button 2d.
Review power connection.
a) Clean.
b) Clean with cleaning solution.
c) Change them.
d) Calibrate photometer
e) Insert the compensating value of water
temperature in the equipment through the
programming (only versdion 16647)
a) Check the hydraulic circuit circulation of
PW
b) Verify and do the right connection to the
flow detector.
a) The filter Cleans mesh.
b) To clean the analysis chamber, must
dismantle the stopper of access to the float
(J).
c) To open the valves of enter and exit of the
hydraulic circuit.
Ref: PW Basic-16647-16648-v2-gb-T01
SOLUTIONS