8. - To confirm the value displayed, press the OK button, then
select the menu
FINE
sensors, the limits of the travels and exit the function
- To change the value of the parameters
h
i
use the
and
buttons, press OK to confirm, then select
the menu
and
FINE
YES
sensors, the limits of the travel and exit the function
- To store only the limits of the travel without changing the
obstacle sensor settings, wait 20" without pressing any
button: the unit exits the programming menu and displays
the control panel
22.4 - READING THE CYCLE COUNTER
The HEAVY2 unit takes into account the completed opening
cycles of the gate and, if requested, reports the need for
maintenance after a fixed number of manoeuvres.
There are two counters available:
• Non resettable counter of the opening cycles completed
(
)
total
• Counter showing the cycles to be performed before the next
maintenance (
)
service
This second counter can be programmed with the desired
number of cycles.
1. Press and hold the OK button until the display shows
2. Release the OK button: the display shows
Total : 0
Service : ----
3. To activate the maintenance request select the
function and press OK
4. Set the desired number of cycles (the step consists of 250
cycles)
5. Press OK to confirm the display shows the control panel
When the Service counter reaches 0 the unit sends the request for
maintenance, that can also be signalled in two ways:
1. Warning light: the option relay REL2 closes to activate a
warning light (Chapter 23)
2. Pre-flashing: if you do not connect a dedicated warning light
the unit indicates the request for service through an additional
pre-flashing of 5 seconds at the beginning of each opening
cycle
To disable the signalling it is necessary to access the
counter menu and again program the number of cycles after
which the maintenance will be required.
If set to
, the signalling function for the request for service is
0
disabled and the signal is not repeated.
m
WARNING: maintenance operations should only be
carried out by qualified staff.
and
to store the values of the
YES
and
SEN.A
SEN.C
to store the values of the
CNT
Service
Service
22.5 - PROGRAMMING THE OPERATING
PARAMETERS
1. Press and hold the OK button until the display shows
2. Release the OK button: the display shows:
• the first parameter of the programming menu:
• the currently set value (
• a scroll bar useful for detecting the position of the
parameter within the programming menu
• a message describing the parameter
MODE STAN
Working mode
3. To change the value of this parameter press the OK button:
the arrows move to the the value
MODE STAN
4. Select the desired value using the buttons
5. Press the OK button to confirm and exit the parameter.
The display shows again:
MODE STAN
h i
6. Using the buttons
parameters: the following pages show a table with all
programming values, the selectable values. the values set by
DEFAULT and a short description of the function.
NOTE: If you hold the buttons
configuration menu scroll in a fast way, until the item
displayed
m
The last menu item
the programming menu and return to normal operation of the
system.
To avoid losing your configuration is mandatory to exit from the
programming mode through this menu item.
m
CAUTION: if you do not carry out any operation for
more than 1 minute, the unit exits from the programming
mode, without storing the settings and changes made are
lost.
- 51 -
MODE
)
STAN
h
i
and
and OK select and edit the necessary
h
i
or
the items of the
FINE
stores the changes made, exit
FINE
PRG
is