Service/Maintenance - Dustcontrol DC 5900H Asbest Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
Emptying
a – Container
The container underneath the cyclone should be emptied when about 2/3 full.

Service/Maintenance

WARNING
The manufacturer or a trained person must carry out an inspection at least once a year. Check, for example, if
the filters are damaged, the dust extractor's air tightness and the operation of the control unit, and inspect the
electrical components, seals and cables for equalization so that they are not damaged.
Filter change
The following safety precautions should generally be followed before starting maintenance:
1.
The machine must be disconnected from the power supply during cleaning and maintenance.
WARNING
Service must never take place inside the zone.
2.
To avoid the spread of dust, the machine must be vacuumed and wiped clean and the suction openings be blocked, for
example with plugs, before the machine is taken from the contaminated area.
3.
All machines must be considered as contaminated if they are removed from the hazardous zone. Appropriate measures must
be taken to prevent the spread of dust.
4.
At maintenance or repair, all contaminated objects that have not been cleaned satisfactorily must be disposed of. Such items
must be disposed of in dust-proof sacks in accordance with the regulations applicable to the disposal of waste.
5.
Clean the machine before disassembling.
6.
A room with filtered, forced ventilation is recommended.
16
DC 5900H, Art.nr. 94380-B