• Attach service leads to terminal board as shown on
luminaire wiring diagram.
• See table below for screw torques (See Table 1).
TABLE 1. Terminal Board Torque Table UL Units
Wire Range Copper
Aluminum
10 - 16 SOL, STR
8 - 6 SOL, STR
STR6 SOL, STR
5
PHOTOELECTRIC CONTROL
• When used, photoelectric (PE) receptacle should be
oriented so that the word "North" is directed toward
true north.
• This is done by seating a PE control into receptacle,
lifting upward on PE control (which will lift PE
receptacle also), and rotating them clockwise until
word "North" is directed toward true north.
lower PE control and receptacle to
Then
them into position. No tools are required to make this
adjustment.
• Alternatively, PE receptacle can be oriented
before PE control is installed. This is done by lifting up
on rim of the PE receptacle and rotating it until the
word "North" is directed toward true north.
Lower
PE receptacle to
Then install PE control.
6

FINAL ASSEMBLY

• To complete installation, carefully close door ensuring
that no wires are obstructing door being fully closed.
• Latch should engage and hold the door closed.
• Inspect latch to be sure it is fully engaged.
• If door screw option is present, door screw may be
tightened after the latch is engaged.
Torque (in lbs)
30
45
seat
seat it in this position.
Door Latch
7

MAINTENANCE / CLEANING

Risk of electric shock. Make certain power is
attempting any maintenance.
maintain high
To
cleaning of the outer lens surface may be needed,
with frequency dependent on local conditions.
• Use a mild soap or detergent, which is essentially
neutral pH (pH approximately 6 to 8), nonabrasive,
and which contains no chlorinated or aromatic
hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
8
STORAGE
• Prior to installation, units should NOT be stored
outside in corrugated boxes (cardboard boxes) alone.
installation, all units should be placed in a
Until
covered dry storage area. The storage area should
not exceed -40°C (-40°F) to 50°C (122°F).
-
This can be preferably in a roofed area or with a
tarp that is secured in such a way to keep water
of the corrugated boxes (cardboard boxes).