WIRING
Note: Make all electrical connections in accordance with
National Electrical Code and any applicable local code
requirements.
Note: Verify supply voltage matches nameplate rating
before wiring.
• Verify service leads meet nameplate temperature rating
• Units are provided with cable or leads exiting the
fixture for connection with service leads.
• If cable or leads are removed and customer connects
service leads directly to the terminal board, see Table 1
for screw torque requirements.
Table 1. Terminal Board Screw Torque (UL Units):
Wire Range Copper
10-16 SOL,STR
8-6 SOL,STR
Wired Dimming
• Connect wired dimming control leads per Table 2.
Table 2. Wired Dimming Control Connections:
0 VDC (-)
Up to 10 VDC (+)
4
AIMING
FIGURE 4. Aiming Sight
An "aiming-sight" for point aiming is provided on the
top of the luminaire.
• Tilt or Rotate luminaire to align the front and rear
sights so that equal space shows on either side and
the desired target point is centered in the groove.
• Tighten trunion or knuckle bolts per instructions in
Section 2.
Aluminum
Torque (in lbs)
30
STR6, SOL, STR
45
Gray Lead
Violet Lead
Front of sight
Target
Rear of sight
60° MAX
FIGURE 5. Maximum Aiming Range with PE
PE Units: Regardless of mounting type, units with a
photoelectric receptacle cannot be aimed more than
60° degrees above horizontal.
5

MAINTENANCE / CLEANING

Risk of electric shock. Make certain power is off before
attempting any maintenance.
• Occasional cleaning of the outer lens surface may
be needed.
• Use a mild non-abrasive soap or detergent,of
neutral pH (pH approximately 6 to 8), which contains
no chlorinated or aromatic hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
6
STORAGE
• Packaged units should NOT be stored unprotected
outdoors in corrugated (cardboard) boxes.
• Store packaged units in a covered dry area not
exceeding -40 °C (-40 °F) to 50 °C (122 °F) such as a
roofed area or covered with a secured tarp to keep
water off the corrugated (cardboard) packaging.
7
CONTROLS
• If using a PE receptacle-based control, refer to
instructions included with control regarding appropriate
settings for dimming and other control features
WARNING