TECHNICAL DATA
POWER REQUIREMENT:
PRESENCE/PULSE RELAY :
RESPONSE TIME:
INDICATOR:
DETECTOR TUNING RANGE:
PROTECTION:
CONNECTOR:
DIMENSIONS:
TEMPERATURE:
SWITCH SETTINGS:
RME 1:
SWITCH SETTINGS:
DIP No.
FUNCTION
10
EXTEND TIME
7,8,9
SENS 0,02%
7,8,9
SENS 0,01%
7,8,9
SENS 0,05%
7,8,9
SENS 0,1%
7,8,9
SENS 0,2%
7,8,9
SENS 0,5%
7,8,9
SENS 1%
7,8,9
SENS 2%
6
FREQUENCY
5
ASB
4
FILTRO
3
PERMANENT PRESENCE
DETECT MODE
2
PULSE MODE
1
PULSE TIME
CH1
PERMANENT PRESENCE DETECT MODE
DIRECTION LOGIC
DET. PULSE MODE (ON DETECTION)
UNDET. PULSE MODE (ON CLEARING)
INSTALLATION MANUAL
RME
200 - 260V~ 50Hz 1,5VA
RME BT
11 - 26V
0.5A/220VAC.
Approximately 120ms after vehicle enters loop.
LED indicators show: Power ,Detect state and Loop Fault.
15 - 1500 uH.
Loop isolation transformer with lightning protection.
11 Pin Connector on rear of unit.
80mm (height) X 40mm (width) X 79mm (Depth excl. connector).
-40°C / +85°C
ON
OFF
2 SEC.
OFF
-
S7/S8/S9
S9
S7/S8
S8
S7/S9
S8/S9
S7
S7
S8/S9
S7/S9
S8
S7/S8
S9
S7/S8/S9
-
LOW
HIGH
ON
OFF
2 SEC.
OFF
PULSE
PRESENCE
UNDET
DET
1 SEC
0,2 SEC
RME 2
DIP 4
DIP 5
OFF
OFF
ON
OFF
OFF
ON
ON
ON
/~ 50/60Hz 95mA max.
RME 2:
SWITCH SETTINGS:
DIP No.
FUNCTION
10
EXTEND TIME
7,8,9
SENS 0,02%
7,8,9
SENS 0,01%
7,8,9
SENS 0,05%
7,8,9
SENS 0,1%
7,8,9
SENS 0,2%
7,8,9
SENS 0,5%
7,8,9
SENS 1%
7,8,9
SENS 2%
6
FREQUENCY
5
PERMANENT PRESENCE
DETECT MODE CH 1
4
PULSE MODE CH 1
3
PERMANENT PRESENCE
DETECT MODE CH 2
2
PULSE MODE CH 2
1
PULSE TIME
CH2
PERMANENT PRESENCE DETECT MODE
DIRECTION LOGIC
DET. PULSE MODE (ON DETECTION)
UNDET. PULSE MODE (ON CLEARING)
ENGLISH
ON
OFF
2 SEC.
OFF
-
S7/S8/S9
S9
S7/S8
S8
S7/S9
S8/S9
S7
S7
S8/S9
S7/S9
S8
S7/S8
S9
S7/S8/S9
-
LOW
HIGH
PULSE
PRESENCE
UNDET
DET
PULSE
PRESENCE
UNDET
DET
1 SEC
0,2 SEC
DIP 2
DIP 3
OFF
OFF
ON
OFF
OFF
ON
ON
ON
RME - RME BT - 9