WARNING
HIGH TEMPERATURE STRESS HAZARD
This room air conditioner is not meant to
provide unattended cooling or life support
for persons or animals that are unable to
react to failure of the product.
The failure of an unattended air conditioner
may result in extreme heat in the conditioned
space causing overheating or death of
persons or animals.
Precautions must be taken to ward off or
guard against such an occurrence.
II. Unpacking
When unpacking visually inspect the unit. Report any
damage to the delivering carrier immediately. Remove and
discard all packing material. On some models the air
conditioner front and/or mounting kit hardware may be packed
separately.
Record the model, serial and manufacturing numbers of your
unit in the space provided below. This information is found on
a nameplate visible on the right hand side of the air conditioner
outer case. The rated voltage, amperage and capacity for
your specific model can also be found on this nameplate.
Read the warranty provided on the last page of this manual.
Keep this manual and a copy of your sales receipt for future
reference. You may also want to record in the space provided
the date purchased and the selling dealer.
OWNER'S PRODUCT IDENTIFICATION
MODEL NUMBER
SERIAL NUMBER
MANUFACTURING NUMBER
Owner's Name
Address
City
State
Zip
/
/
Date of Purchase
Authorized Dealer
Address
City
State
Zip
(
)
Phone Number
III. Electrical Requirements
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong grounding plug
for protection against possible shock hazards. If a two-prong
wall receptacle is encountered, the customer is required to
contact a qualified electrician and have the two-prong wall
receptacle replaced with a properly grounded three-prong
wall receptacle in accordance with the National Electrical
Code.
Room air conditioners are designed to operate according to
requirements on the nameplate and as shown in Table 1.
Fuse or circuit breaker ratings must be according to the fuse
instruction label and as shown in Table 1 and the label on the
electrical cord. Do not plug models marked
Use on Single Outlet Circuit Only
into a circuit with another appliance or light fixture.
To avoid death, personal injury or property
damage due to electrical shock, this unit
must be grounded. Do not under any
circumstances cut or remove the round
grounding prong from the plug. Do not use
a two-prong adapter.
To avoid death, personal injury or property
damage due to electrical shock, do not use
an extension cord. Do not pinch the power
cord. Do not remove the warning tag from
the power cord.
Receptacle
Unit Plug Type
required
NEMA No. 5-15R
NEMA No. 5-15P
NEMA No. 6-15P
NEMA No. 6-15R
NEMA No. 6-20R
NEMA No. 6-20P
NEMA No. 6-30P
NEMA No. 6-30R
2
WARNING
WARNING
Circuit Rating
Breaker or
Voltage Rating
Time
On Unit Nameplate
Delay Fuse
115V
125V-15AMP
230/208V rated
250V-15AMP
at 12 amperes or less
230/208V rated over
12 amperes but not more
250V-20AMP
than 16 amperes
230/208V rated
250V-30AMP
at 24 amperes or less
Table 1