15. Remove the Nose Housing
16. Loosen the Fill Screw
approximately 3 - 3½ full turns or a 0.14'' (3.6 mm) gap to allow excess hydraulic oil
and bubbles to escape.
When no more oil comes out, tighten the Fill Screw (Fig. 7).
17. Wipe off any dirt and oil on the tool.
18. Replace the Nose Housing
Note: During assembly and disassembly, do not allow any metal swarf or dirt into the Hydraulic
Oil and inner Chamber.
MAINTENANCE
ITEM
Clean and lubricate Front
End of tool
Inspect jaws
Collector
SYMPTOM
PROBABLE CAUSE
TOOL FAILS TO OPERATE
Tool not connected to air supply.
VA Valve is in "OFF" position.
Insuffi cient air pressure.
Air pressure is too high.
Tool is low on hydraulic fl uid.
TOOL NOT RETURNING
Possible jam due to debris in Nose Housing.
TOOL LOSING STROKE
Tool low on hydraulic fl uid.
, and tighten the Jaw Guide
by hand until it stops.
and Collector
.

PREVENTATIVE MAINTENANCE SCHEDULE

ACTION
See "Front End Service"
Look for broken jaws and
damage or wear on jaw teeth.
Empty Collector
Clean Collector Silencer

TROUBLESHOOTING

Fig. 7
th H d
li
FREQUENCY
1 x per day or 5,000 rivet settings.
During "Front End Service" or when jaws
slip on mandrel.
When the quantity of stored spent
Mandrels starts to interfere with
mandrels entering the Collector.
(Storage quantity depends on rivet – approx. 50-70
3/16" (4.8 mm) rivets).
Once a week or when suction will not pull spent
mandrels into the Collector.
REMEDY
Connect to recommended air supply source.
Slide VA Valve to ON position.
Adjust air supply pressure.
Adjust air supply pressure.
Service tool by qualifi ed service personnel.
Perform "Front End Service" and check for debris
or damage.
Service tool by qualifi ed service personnel.