Descargar Imprimir esta página
Leviton 47603-ASO Instrucciones Importantes
Leviton 47603-ASO Instrucciones Importantes

Leviton 47603-ASO Instrucciones Importantes

Pre-configured structured cabling panels

Publicidad

Enlaces rápidos

IMPORTANT INSTRUCTIONS
1.
Read and understand all instructions. Follow all warnings
and instructions marked on the product.
2.
Do not use this product near water—e.g., near a tub,
wash basin, kitchen sink or laundry tub, in a wet base-
ment, or near a swimming pool.
3.
Never push objects of any kind into this product through
openings, as they may touch dangerous voltages.
4.
SAVE THESE INSTRUCTIONS.
INSTRUCCIONES IMPORTANTES
1.
Lea y comprenda perfectamente todas las instrucciones. Siga
todas las instrucciones y advertencias marcadas sobre el pro-
ducto.
2.
No utilice estos productos cerca del agua, por ejemplo, cerca de
bañeras, tinas, lavaderos o lavabos, fregaderos de cocina, tinas
para lavandería, dentro de sótanos húmedos, o cerca de piscinas.
3.
Nunca introduzca objetos de ningún tipo a través de las aberturas
de estos productos, ya que pueden hacer contacto con voltajes
peligrosos.
4.
CONSERVE ESTAS INSTRUCCIONES.
DIRECTIVES IMPORTANTES
1.
Lire les présentes directives et s'assurer de bien les compren-
dre; observer tous les avertissements et directives apparaissant
sur le dispositif.
2.
Ne pas installer ce dispositif à proximité d'une source d'eau –
comme une baignoire, un bac à laver, une cuve à lessive ou un
évier de cuisine –, dans un sous-sol humide ni près d'une
piscine.
3.
Ne jamais insérer quelque objet que ce soit dans les ouvertures
de ce dispositif; elles sont sous tension et peuvent présenter un
danger.pourraient entrer en contact avec des tensions dan-
gereuses.
4.
CONSERVER LES PRÉSENTES DIRECTIVES.
2222 - 222nd Street SE
Bothell, WA 98021, USA
Phone: (425) 485-4288
Fax: (425) 483-5270
SAFETY INFORMATION
1.
Never install communications wiring or components dur-
ing a lightning storm.
2.
Never install communications components in wet loca-
tions unless the components are designed specifically for
use in wet locations.
3.
Never touch uninsulated wires or terminals unless the
wiring has been disconnected at the network interface.
4.
Use caution when installing or modifying communications
wiring or components.
5.
To prevent electrical shock, each opening must be filled with a
module.
INFORMACIÓN SOBRE SEGURIDAD
1.
Nunca instale cableado o componentes de comunicaciones
durante una tormenta eléctrica.
2.
Nunca instale componentes de comunicaciones en un local
mojado, a menos que los componentes hayan sido diseñados
especificamente para uso en locales mojados.
3.
Nunca toque alambres o terminales sin su cubierta, a menos
que el cableado haya sido desconectado en el interfaz de la red.
4.
Use precaución cuando esté instalando o modificando cableado
o componentes de comunicaciones.
5.
Para impedir choques eléctricos, se debe cubrir cada abertura
con un módulo.
CONSIGNES DE SÉCURITÉ
1.
Ne jamais effectuer l'installation de câblage ou de composants de
communication pendant un orage.
2.
Ne jamais installer de composants de communication dans des
endroits mouillés à moins qu'il s'agisse de dispositifs conçus
spécialement pour cet usage.
3.
Ne jamais toucher des bornes de raccordement ni du fil non
isolés, à moins que le circuit ne soit pas relié à l'interface
réseau.
4.
On doit prendre toutes les précautions requises lorsqu'on
installe ou modifie du câblage ou des composants de télécom-
munication.
5.
Afin d'éviter les chocs électriques, toutes les ouvertures doivent
être dotées d'un module.
47603-ASO 47603-BHN 47603-18P
47603-AHT 47603-BTV 47603-24P
Pre-Configured Structured Cabling Panels
APPLICATION
One of six Pre-Configured Structured Cabling Panels, which may be used to connect basic telephone
service, data (with a network hub) and, on selected versions, video service for home or office cabling.
Panels are designed to fit into Structured Media Centers™ (Models 100, 140, 280 or 420), or plastic
mounting hardware may be removed and unit may be screwed directly onto a plywood backboard.
PLANNING
Your Pre-Configured Structured Cabling Panel may consist of one or more of the following components: a
1x9 Bridged Telephone Module, a Category 5e Voice and Data Module, a Telephone Distribution Module
or a 6-way Video Splitter.
Plan all of your cable routing carefully to be sure the selected distribution panel will satisfy your
requirements. Determine the number of outlet locations required for basic phone, fax, modem and TV
service. Additional Category 5e Voice and Data Modules (PN# 47603-C5) and 1x9 Bridged Telephone
Expansion modules (PN# 47603-110) are available separately.
Modules:
Your Pre-Configured Structured Cabling Panel consists of one or more of the following modules:
Category 5e Voice and Data Module: used for terminating remote connections (from wall outlets) for voice,
fax, modem and computer. Use it to provide dial tone to an outlet, or to link to a network hub.
Telephone Distribution Module: accepts incoming service from the telephone service provider (dial tones)
and provides dial tone (for up to 4 lines) to ports on the Category 5e Voice and Data Module by way of
short patch cords.
1x9 Bridged Phone Module: used for connecting up to four phone lines for voice, fax and modem in a
bridged wiring configuration.
6-way Video Splitter: routes basic video signals from one input to as many as six remote televisions.
[Should local signal need active attenuation, optional video module will be required (PN#48210-VA).]
Installation:
Position the Structured Cabling Panel inside the SMC enclosure. Align the plastic Push Lock Pins (plunger
out) on the distribution panel with the appropriate mounting holes on the enclosure. Seat the panel in
place, resting flat against the back of the panel, and then press the Push Lock Pins inward with your
thumb to lock into place. You will know the push locks are secure if they "click" when pressing in.
Typical wiring of an SMC 140 shown, using an
Advanced Small Office Pre-configured Structured
Cabling Panel.
PK-93091-10-02-0A
1

Publicidad

loading

Resumen de contenidos para Leviton 47603-ASO

  • Página 1 IMPORTANT INSTRUCTIONS SAFETY INFORMATION 47603-ASO 47603-BHN 47603-18P 47603-AHT 47603-BTV 47603-24P Read and understand all instructions. Follow all warnings Never install communications wiring or components dur- and instructions marked on the product. ing a lightning storm. Do not use this product near water—e.g., near a tub,...
  • Página 2 CATEGORY 5e VOICE & DATA MODULE Client Notes/Notas del usuario/Notes de l’utilisateur: UTP to Wallplates Connecting the Category 5e Voice and Data Module Run twisted pair cable to the Category 5e Voice and Data Module from wall outlets. Strip about 3˝ of outer jacket from the cable. Punch individual cable pairs down on the six white connectors on the sides of the Module.
  • Página 3 6 câbles coaxiaux. Offerte en 2=orange, Line 3=green, line 4=brown). 47603-ASO version autonome ou sous forme de composant des CMS 100 et NOTE: The secondary line on a two-line telephone is represented by the orange/white pair.
  • Página 4 Will distribute 12 cables for voice/telephone and/or data networking with 6 for video. Available as a stand-alone unit, or LES PANNEAUX SUIVANTS SONT OFFERTS PAR LEVITON : as part of a kit with SMC-100 or SMC-140. Unité téléphonique et vidéo de base : 47603-ASO Dimensions 6.25˝h x 13.06˝w x 2.50˝d...
  • Página 5 Utilisation du module de distribution téléphonique avec celui de transmission de données/de Paneles de Cableado Estructurado Pre-Configurados la voix de catégorie 5e. APLICACIÓN: Pour répartir le service téléphonique d'un module de distribution aux diverses prises murales d'une Uno de los seis paneles de cableado estructurado pre-configurados que pueden usarse para conectar résidence ou d'un bureau, il suffit de raccorder un cordon de connexion entre la colonne appropriée du servicio telefónico básico, datos (con una terminal de red) y, en algunas versiones, servicio de vídeo para module de distribution et le point de connexion désiré...
  • Página 6 MODULE DE TRANSMISSION DE DONNÉES/DE LA VOIX DE CATÉGORIE 5e MÓDULO DE VOZ Y DATOS CATEGORÍA 5e PTNB aux UTP a las tomas prises murales Raccordement du module de transmission de données/de la voix de catégorie 5e Conexión del Módulo de Voz y Datos Categoría 5e de pared Acheminer le câble à...
  • Página 7 Panneaux de câblage structurés préconfigurés APPLICATIONS Blanco/Azul Blanco/Verde On peut se servir de n'importe lesquels de six panneaux de câblage structurés préconfigurés pour Azul/Blanco Verde/Blanco distribuer le service téléphonique de base, les lignes de transmission de données (en présence d'un Blanco/Naranja Blanco/Naranja Naranja/Blanco...
  • Página 8 Voz y Datos Categoría 5e en un soporte dedicado a sistemas de multi-línea y operación en red de casa expandido. Distribuye 24 cables para voz/teléfono y/o datos de operación en red. LEVITON TIENE DISPONIBLES LOS SIGUIENTES PANELES: Está disponible solamente como unidad individual. Unidad Básica de Teléfono y Vídeo:...
  • Página 9 Connect a security system to the module via a téléphoniques entrantes dans les résidences ou les bureaux pour les Leviton y para distribuir servicio telefónico a todo el hogar u oficina dedicated Security Port, providing over-ride protection in case of applications vocales.
  • Página 10 NOTE: A label to the right of each port on the TLDM indicates the lines 1. Distribuya el cable Categoría 5e desde cada roseta hasta el 1. Acheminer un câble de catégorie 5e entre chaque prise murale et le served. module de transmission de la voix/de données.

Este manual también es adecuado para:

47603-bhn47603-18p47603-aht47603-btv47603-24p