CATEGORY 5e VOICE & DATA MODULE
Connecting the Category 5e Voice and Data Module
Run twisted pair cable to the Category 5e Voice and Data Module from wall
outlets. Strip about 3˝ of outer jacket from the cable. Punch individual cable
pairs down on the six white connectors on the sides of the Module. Match the
color coding of the wires to the colors on the connector. If you do not have a
professional grade termination tool, use the plastic tool supplied with the
module. (See 110 Punchdown Procedure.) All four pairs of each cable must be
terminated. (The module supports T568A wiring pattern – See figure 2.)
Punch the individual conductors down onto the appropriate connections. If you
are using the plastic tool, make sure you trim the excess wire ends with a
separate tool, such as a side cutter.
Use ports to route telephone service to wall outlets, or to connect to a data hub.
(Ports will accept both 6 and 8-position plugs.)
TELEPHONE DISTRIBUTION MODULE
Connecting the Telephone Distribution Module
Run twisted pair cable to the Telephone Distribution Module from the telephone
company demarcation point. Strip about 3˝of outer jacket from the cable. Punch
individual cable pairs down on the white connector at the top of the Telephone
Distribution Module. If you do not have a professional grade termination tool,
remove excess wire with side cutters.
NOTE: One pair of wires corresponds to each line from the phone company.
(Line 1=blue, Line 2=orange, Line 3=green, Line 4=brown.) (See Figure 2.)
By punching incoming Telco lines at the top of the Telephone Distribution Module,
the lines will be routed to the three columns of ports. The short (3˝) 8-position
patch cord on the left of the module acts to provide this bridge between the
incoming lines and the columns of jacks below. (This is also a disconnect point
between the home and the telephone service provider for testing purposes.)
Line 1 and Line 2 will both be carried to the first column of ports, which provides two-line phone service
for multi-line phones. (For single-line phones, only Line 1 will be accessible.) Line 3 will be carried to the
second row, and Line 4 to the third. These ports are single-line only.
An RJ31X port on the top left of the module will allow connection of a security system, and allow an
override of telephone services in case of emergency.
Using the Telephone Distribution Module with the Category 5e Voice and Data Module
To connect phone service from the Telephone Distribution Module to the various wall outlets around the
home or office, simply connect a patch cord from the appropriate column on the Telephone Distribution
Panel to the desired port on the Category 5e Voice and Data Module. (See figure 1.)
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
White/Brown
Brown/White
1
2
PK-93091-10-02-0A
UTP to
Wallplates
Incoming Telephone
Service
White/Green
Green/White
White/Orange
Orange/White
White/Blue
Blue/White
White/Brown
Brown/White
2
3