American Standard Advanced Clean 100 Combo Manual Del Usuario página 34

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Useful Information
Draining the Water to Prevent Freezing
1 Set the 【Seat Temp.】 to "High" and close
lid ( ☞ Page 9).
the SpaLet
®
2 Turn off any active power save function
( ☞ Page 21).
3 Manipulate the water drain plug in your
building to drain water from the pipes.
* Do not close the water shutoff valve when
manipulating the water drain plug.
4 Press the 【Flush Full】 button or press the
flush button on the SpaLet body.
* Wait approximately 20 seconds.
* Confirm that the water does not flow when
attempting to flush the SpaLet.
5 Drain water from the SpaLet body
* Refer to steps 3 and 4 of the "Draining Water"
procedure on page 43 to drain the water from the
SpaLet bowl.
6 Reattach the side cover ( ☞ Page 42).
■ Reusing the SpaLet
Always perform the necessary preparations and
checks before use. ( ☞ Page 7)
31 - EN
■ If water has frozen and the SpaLet does not
operate or if the water supply hose or water supply
connections have frozen and the SpaLet does
not operate, use a cloth immersed in warm water
to warm the water supply hose or water supply
connections to slowly thaw them, or warm the
bathroom and allow them to thaw naturally.
[CAUTION]
● Do not pour hot water or blow hot air over the
water supply hose.
* Doing so may result in damage to the water
supply hose.
● Water may be discharged during the thawing
process depending on the parts being warmed.
Confirm the condition regularly during the thawing
process.

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido