Verderflex VP-PRO – PH/RX Manual De Regulatión página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

STAND BY (STOP)
Push and hold the ESC/SBY button for 2 seconds during the functioning to put the pump in stand by
mode:
1) It stops dosing
2) Green on led blinks.
3) If the functioning is PROPORTIONAL the display shows: "Stop 0%" on the first row and the current
measure on the second row (see figure on the left side, the example refers to a pH type)
3) If the functioning is Manual or ON-OFF the display shows: "Stop" and the % programmed
frequency on the first row and the current measure on the second row (see figure on the left side, the
example refers to pH type)
Push again the ESC/SBY button for 2 seconds to return the pump to the programmed functioning.
MENU TREE
LANGUAGE SELECTION
Push and quickly release CAL button and then pressing + and – buttons select the language
choice. Push CAL to enter the language submenu and select "Language English" by pressing
+ or - .
Push CAL to confirm the choice and ESC to go back in measuring.
MEASURE TYPE CHOICE
DELAY START
WHAT IS IT? The delay start is the time in seconds (0-999sec) after the power on that the
pump waits before dosing the chemical product. During this period of time the display shows
the message "Delay" on the first row and the measure on the second row (see figure on the
left side). During the delay start the pump can't dose but it is possible to enter the menu and
modify the parameters and calibrations.
TIME ALARM
Rev 1.0
Push and quickly release CAL button and scroll the menu using + and –
buttons till the display shows "Measure Type". Push CAL to enter the
submenu and then by pressing + and – button choice pH or Rx measure.
Push CAL to confirm and ESC to go back in measuring.
DELAY START EDITING
Push and quickly release CAL button and scroll the menu using + and –
buttons till the display shows "Delay Start". Push CAL to enter the
submenu and then by pressing + and – button choice the value in seconds
(0-999). Push CAL to confirm and ESC to go back in measuring.
WHAT IS IT?
The Time alarm is expressed in units (0-120unit) of dosage. One unit is
equivalent to 1 minute of chemical dosing. The units counting starts from 0 when the pump starts
dosing after the power on, increases during dosing, stops during level alarm and stand_by state,
and is resetted when the power is off, when the measure reaches the setpoint and during the
flow alarm. When the counting reaches the value memorized in Time alarm the pump goes in
Time Alarm state:
Cod. 00.008.646
Push and quickly release CAL
button during the functioning to enter
into the programming menu.
Push + or - button to navigate
through the menu.
Push the CAL button to enter the
submenus.
12

Publicidad

Tabla de contenido
loading

Tabla de contenido