Function as interface
Registration with VELUX INTEGRA
wall switch KLI
®
The illustrations below show
how you copy the contents from
1
a wall switch KLI (2a or 2b) to
interface KLF 200.
A
B
1
Connect the interface to the mains supply and connect the supplied wire
bundle to input terminal. When light-emitting diode 1 flashes yellow, the
interface is ready for configuration.
2a
1 sec
Press the Gear button on the wall switch for 1 second. The product runs
briefly back and forth.
2b
10 sec
L R
L R
Press the R button on the back of the wall switch for 10 seconds.
The light-emitting diode flashes green and the products run briefly back
and forth.
ENGLISH
VELUX
19
®