Descargar Imprimir esta página

Celestron 47009 Manual De Instrucciones página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Press "RAIN HISTORY" repeatedly to scroll through the history data corresponding to your
selection. On the bar shown in the rainfall display area, the "0" represents the current period
and the "-1", "-2", etc. indicate the prior periods. As an example, during the month of April,
press the "RAIN HISTORY" button repeatedly in the monthly mode until "-3" bar chart is
shown. The bar chart and reading indicate the monthly rainfall record for the month of January
st
st
(1
through 31
Alarm Setting – press the "ALARM" button to show the alarm time and the "ALARM" icon
will appear. Press again to enable or disable the alarm – when enabled a bell icon will appear".
Press and hold the "ALARM" button to
enter the setting mode. Enter the desired
hour and minute values by pressing the
"UP" and "DOWN" button and then
pressing "ALARM" to set each.
Snooze – when the alarm goes off, press
"SNOOZE/LIGHT"
Receiver) to go into snooze mode and the
alarm will go off again in 10 minutes and
continue over and over as long as you hit
the "SNOOZE". To stop the snooze or
alarm, press the "ALARM" button.
Channel – if your Sensor is set correctly to Channel 1, then a small icon to the left of wind chill
display will show "ch1". If you do not have an outdoor temperature and humidity display, make
sure that the "1" is displayed and if not (shows a 2 or 3), then push the "CH" button until is
shows the "1".
Low Battery Indication – the Receiver and remote sensors will be display an icon and you
should change batteries as soon as possible.
Placement – the Receiver can be put on a table, desk, or other flat surface or it can (by using a
hanger cut out (in two places) on the rear of the Receiver) be hung on a wall or other location.
Specifications:
Indoor Temperature Range = 0º to +50º C (+ 32º to + 122º F)
Remote Sensor Temperature Range = -20º to + 60º C ( -4º to + 140º F)
Indoor/Outdoor Humidity Range = 20% to 99% Relative Humidity
Resolution = ± .5º C (± 1.5º F) for temperature & ± 1.5% humidity
Wind Speed Range = 0 to 108 km/h, 0 to 67 mph, 0 to 30 m/s, 0 to 58 knots, 0 to 11 Beaufort
Rain Gauge Reading = 0 to 9999mm, 0 to 394 in
Clock = digital quartz
Transmission = RF433 MHz
Dimensions = Receiver – 7.6" x 1.1" x 4.5" (193x28x114mm) Anemometer/Sensor – 8.0" x 7.8" x
14.3" (203x198x363mm) Rain Gauge – 5.8" x 2.3" x 3.3" (147x58x84mm)
Weight = Receiver - 15oz/425g
2835 Columbia St.
Torrance, California 90503 U.S.A.
www.celestron.com
Printed in China 0110
).