ATTENTION:
This operation must be carried
out using gloves to protect from
contact with dangerous solu-
tions.
CLEANING OF THE SOLU-
TION FILTER
1. Empty the detergent solution
tank as indicated in paragraph
"CLEANING OF THE SOLU-
TION TANK".
2. Unscrew the cap of the ex-
haust filter (1).
3. Rinse the filter placed inside
the cap, paying attention not to
lose the gasket of the cap.
4. Rinse the hose pouring some
water into the solution tank.
5. Reassemble all parts.
ATTENTION:
This operation must be carried
out using gloves to protect from
contact with dangerous solu-
tions.
TWO-MONTHLY MAINTE-
NANCE
FRONT SQUEEGEE RUBBER
CHECK
Check the wear of the squee-
gee rubber and eventually
replace it.
For the replacement it is neces-
sary to:
1. Release the squeegee from
the support as indicated in para-
graph "SQUEEGEE CLEAN-
ING".
2. Unscrew the wing nuts in the
front part of the squeegee.
3. Take off the rubber holder
blade.
4. Replace the front rubber.
5. Reassemble all parts.
SIX-MONTHLY MAINTENANCE
SPLASH GUARD RUBBER
CHECK
1. Open the hooks in the rear
part of the brushes base group
from the slot placed at the ex-
tremity of the metal strip.
2. Replace the splash guard
rubbers and follow assembling
instructions as under paragraph
"SPLASH GUARD ASSEMBLY".
With brushes assembled, the
splash guard must slightly touch
the floor.
CLEANING OF THE INNER
FILTER SOLUTION TANK
Clean regularly the internal filter
of the solution tank which is in
the rear low part of the machine.
19
Empty the solution tank, remove
the fitting of the water outlet by
taking off the two screws which
fix it to the tank. Clean the in-
side part of the fitting of dirt and
debris. Pour some water into
the tank to clean it. Reassemble
the fitting onto the solution tank.
CHECK OF THE BRAKE
Check the braking efficacy
and that both pads (1) which
act upon the traction wheels,
in resting position, have got a
distance of not more than 3 mm
from the wheels. If necessary,
adjust them through the fixing
nuts (2).
The checking of all the other
foreseen machine operations is
left to the authorized technical
assistance.
TROUBLESHOOTING GUIDE
THE SUCTION MOTOR DOES
NOT WORK
1. Verify that the key switch (9)
is in the correct position.
2. Check the charge level of the
batteries on the display (1).
3. Check that the battery con-
nector is correctly plugged in.
4. Verify that the switch (3) is
on.
5. Check that the red connector
of the suction motor is correctly
plugged in.
If the problem persists, please
contact the authorized technical
assistance.