900CT - 2
SKL - 2
MANUALE ISTRUZIONI
I
INSTRUCTION MANUAL
GB
LIVRET D'INSTRUCTIONS
F
ANLEITUNGS HEFT
D
MANUAL DE INSTRUCCIONES
E
MANUAL DE INSTRUÇÕES
P

Publicidad

Tabla de contenido
loading

Resumen de contenidos para minikon 900CT-2

  • Página 1 Centralina elettronica Control unit Armoires de commande Steuerung Récepteur Centralitas Unidades de controlo 900CT - 2 SKL - 2 MANUALE ISTRUZIONI INSTRUCTION MANUAL LIVRET D’INSTRUCTIONS ANLEITUNGS HEFT MANUAL DE INSTRUCCIONES MANUAL DE INSTRUÇÕES...
  • Página 2: Tabla De Contenido

    INDEX I GB INDEX MODELS AND FEATURES TECHNICAL DATA SET PANEL 900CT-2 TERMINAL BOARD CONNECTIONS SET PANEL 900SKL - 2 INSTALLATION 7 - 8 STANDARD OPERATION STANDARD OPERATION OPTIONS TESTING MAINTENANCE / DISPOSAL THIS HANDBOOK IS APPOINTED FOR THE INSTALLER ONLY...
  • Página 3: Models And Specifications

    MODELS AND SPECIFICATIONS Control unit 230V box for two motors, with electric clutch, logical 900CT-2 control card,pre-set for radio card insertion. TECHNICAL DATA SUPPLY 230Vac/50-Hz OUTPUT SUPPLY 24Vdc/400mA ACCESSORIES OPERATING TIME 2-60 sec PAUSE TIME 2-180 sec PROTECTION DEGREE IP 54 OPERATING TEMPERATURE -20°/+70°...
  • Página 4: Set Panel 900Ct

    SET PANEL 900CT-2 min. TRANSFORMATOR max. com. c.a. PLACA DE RÁDIO 2ch. ant. PLACA DE LÓGICA SKL-2 Fus. p.p. 6,3a STOP ap. foto fo.2 230 Vac...
  • Página 5: Terminal Board Connections

    TERMINAL BOARD CONNECTIONS 230VAC 230Vac 50 Mhz mains power supply. Outlet for flashing/courtesy lamp (selection between FLASHING UNIT flashing unit and courtesy lamp is set on the relative J2 jumper) max. 230Vac 25W for flashing unit, max. 100W for courtesy lamp. 5-6-7 MOTOR M1 Output for motor 1 with delay on opening;...
  • Página 6: Set Panel 900Skl

    SET PANEL 900SKL-2 1 DIP SWITCH FUNCTION See standard operation options. 2 TRIMMER TP Adjustment of pause time before automatic gate closing from 2sec to 3min. 3 TRIMMER TL Adjustment of motor working time from 0 to 60 sec. TRIMMER TR Adjustment of closing delay time of motor M2 from 2 to 10 sec J1 - J2...
  • Página 7: Installation

    INSTALLATION Device installation must be carried out professionally by personnel with qualifications as specified by current legislation. To guarantee safety of the operator and prevent damage to parts during connections, both low voltage (230 V) and very low voltage (24 V) or when connecting the radio card, the control unit must always remain disconnected from the power supply.
  • Página 8 The pedestrian command enables opening of one gate leaf PEDESTRIAN on a 2-leaf model. If dip switch 1 is selected (sliding mode) the gate opens for 1/3 of the working time. The gate open indicator lamp notifies the user of the gate status. Gate closed - lamp off.
  • Página 9: Standard Operation Options

    STANDARD OPERATION OPTIONS NORMAL/APARTMENT BLOCK OPERATION - This selection enables JUMPER J1 modifications to the operation of the PP input in apartment blocks; on each command via radio or pushbutton opening is activated. FLASHING UNIT/COURTESY LAMP FUNCTION - This enables the JUMPER J2 user to select whether to enable the output for a flashing unit or that of a courtesy lamp.
  • Página 10: Testing

    TESTING Testing of the entire system where the control unit is installed must be performed by qualified personnel who must conduct all tests according to the associated risks. BEFORE POWERING UP THE AUTOMATION - check all connections - set all trimmers to minimum - set all dip switches as required - set the adjustment trimmer to minimum power On completion of the above, the unit can be started up.