Device installation must be carried out professionally by personnel with qualifications as specified by
current legislation.
To guarantee safety of the operator and prevent damage to parts during connections, both low voltage
(230 V) and very low voltage (24 V) or when connecting the radio card, the control unit must always
remain disconnected from the power supply.
Always keep power supply cables separate from control cables. In the case of power cables, motor lines,
flashing unit/courtesy lamp lines and electric lock, use cables with a minimum section of 1,5 mm 2;
in the case of auxiliary utilities, commands and safety contacts, use cables with a minimum section of
0,5 mm 2. When control cables are very long (over 30 m) disconnection by means of relays in the control
unit is recommended.
If a fuse trips, after eliminating the cause, replace with a version with the same characteristics.
Install all safety devices, limit switches, photocells, safety edge, and stop pushbutton.
If one or more of the safety devices are not installed, insert a jumper in the relative
terminals with the controls common contact.
All N.C. contacts related to the same input must be connected in series.
All N.O. contacts related to the same input must be connected in parallel.
Install disconnection elements on the mains power supply in an accessible location.
STANDARD OPERATION
OPEN
CLOSE
STOP
STEP
INSTALLATION
The open command activates the flashing unit and then starts gate opening.
The close command activates the flashing unit and then starts gate closing.
The stop command stops the gate and awaits a new command.
The step command acts on the gate via a radio control or pushbutton,
setting the system to different phases:
- from gate open it anticipates the closing phase
- from moving gate it changes to the stop phase
- from closed gate it changes to the opening phase