Type (1/4 turn electric actuator)
Housing type
IP protection (EN60529)
Corrosion resistance (outdoor and
indoor use)
Temperature
Hygrometry
Pollution degree
Altitude
Sound level
Weight
Nominal torque
1/4 turn travel time
Mounting actuator base (ISO 5211)
Swing angle
Mechanical end stops
Manual override
Direction of rotation
Voltage ±10%
Frequency
Power consumption
Overvoltage category
Torque limiter
Duty cycle (CEI34)
Limit switches maximal voltage
Limit switches maximal current
Electrical wiring
Inrush current
DSBA3100 • Rév. 17/07/2020
TECHNICAL DATA
ER20
Small housing (see p.13)
Housing: PA6 UL94V0 + 25% GF and cover: PA6 UL94V0
Raw material : 304L Stainless Steel or Steel + Zn treatment
maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly
Applicable POLLUTION DEGREE of the intended environment is 2 (in most cases).
1 Kg
MECHANICAL DATA
20Nm
13s
Star 14
F03-F04-F05
ELECTRICAL DATA
24V AC 50/60Hz or 100V to 240V AC 50/60Hz
15W (0.08A) cos j = 0.75
TRANSIENT OVERVOLTAGES up to the levels of OVERVOLTAGE CATEGORY ll
TEMPORARY OVERVOLTAGES occurring on the MAINS supply
1 ISO M20 cable gland and 1 DIN43650 3P+T connector
Circuit breaker type D, nominal current according the number of actuators (max. 4 actuators) or
use a inrush current limiter at the output of the circuit breaker.
ER35
ER60
large housing (see p.13)
IP65
-10°C to +55°C
to 50 % relative humidity at 40 °C
altitude up to 2 000 m
61 dB
2.1 Kg
35Nm
60Nm
8s
Star 22
F05-F07
90° (others on request)
90° +/- 5°
Out axle
Anticlockwise to open
24V DC or 100V to 350V DC
50/60Hz
45W (0.15A) cos j = 0.75
Electric
30%
4 to 250V AC/DC
(Overvoltage category II)
1mA to 5A max
ENGLISH
UK
ER100
100Nm
15s
25s
17