FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED
LICENSED ELECTRICIAN
1.
Connect dryer to nearest distribution panel. Use wire as required by local electrical code. In the United States and Canada
use No. 12 wire or larger.
2.
Wiring Instructions:
a. This appliance is intended for connection to fixed wiring.
b.
A fused means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules.
c.
Check that the electrical rating shown on the Hand Dryer (rating label) is compatible with the electrical supply.
d.
WARNING: THIS PRODUCT MUST BE EARTHED.
e.
Installation and wiring must conform to current IEE Regulations (UK), local or appropriate regulation (other countries).
For 115 Volt Dryers: Connect ground/earth supply the terminal marked
f.
neutral supply to terminal marked N. A DEDICATED LINE IS REQUIRED FOR EACH 115 VOLT DRYER.
g.
For 208–240 Volt Dryers: Connect ground/earth supply the terminal marked
marked L (L1) and N (L2).
3.
Secure electrical wire in strain relief clamp provided on mounting base.
1. Fit cover over mounting base.
NOTE: Four sides of cover overlap the
mounting base and should be flush with
the sides, top and bottom of the mount-
ing base.
1. Turn electrical power supply on.
2. Position hands under air-outlet, within 4'' (100mm) of the bottom of the dryer.
3. Dryer should turn on. Warm air should blow from air-outlet. Drying time less than 25 seconds.
4. Remove hands from under air-outlet and dryer should stop (within 2 seconds).
WARNING: MOTOR LAMINATIONS ARE LIVE. TURN ELECTRICAL POWER SUPPLY OFF BEFORE DOING ANY
MAINTENANCE OR SERVICE TO DRYER. DRYER MUST NOT BE OPERATED UNLESS COVER IS IN PLACE.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED
LICENSED ELECTRICIAN
1.
Exterior of cover should be cleaned with a damp cloth to remove dust and surface dirt. Do not use abrasive agents or solvents as
they may permanently damage surface of cover.
2.
At least once every 6 months remove cover. Using a small brush or vacuum, clean out buildup of dust and lint from air-intake
grille and baffle.
NOTE: if dryer is installed where there is a lot of dust and dirt in the air, the interior of the dryer should be cleaned out more
frequently.
Electrical Connection
Replace Cover
Check Dryer Operation
Maintenance
Form No. 712-69 Multi Language (Rev. 2/19/18)
, the Live supply to terminal marked L and
and the 208-240 Volt wires to terminals
2. Replace and tighten two screws,
on the bottom to secure cover to
mounting base.
© 2018 Bobrick Washroom Equipment, Inc.
3