Victron energy BlueSolar MPPT 100/30 Manual página 13

Ocultar thumbs Ver también para BlueSolar MPPT 100/30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5. Specifications
BlueSolar charge controller
Battery voltage
Maximum battery current
Maximum PV power, 12V 1a,b)
Maximum PV power, 24V 1a,b)
Maximum PV open circuit voltage
Peak efficiency
Self consumption
Charge voltage 'absorption'
Charge voltage 'equalization'
Charge voltage 'float'
Charge algorithm
Temperature compensation
Protection
Operating temperature
Humidity
Maximum altitude
Environmental condition
Pollution degree
Data communication port and
remote on/off
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
Safety
1a) If more PV power is connected, the controller will limit input power to
440W resp. 880W.
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V.
MPPT 100/30
12/24 V Auto Select
440 W (MPPT range 15 V to 80 V)
880 W (MPPT range 30 V to 80 V)
Less than 10 mA
Default setting: 14,4 V / 28,8 V
Default setting: 16,2 V / 32,4 V
Default setting: 13,8 V / 27,6 V
multi-stage adaptive (eight preprogrammed
-16 mV / °C resp. -32 mV / °C
Battery reverse polarity (fuse, not user accessible)
Output short circuit / Over temperature
-30 to +60°C (full rated output up to 40°C)
95 %, non-condensing
Indoor, unconditioned
See the data communication white paper on our website
ENCLOSURE
Blue (RAL 5012)
13 mm² / AWG6
IP43 (electronic components)
IP 22 (connection area)
130 x 186 x 70 mm
STANDARDS
EN/IEC 62109
30 A
100 V
98 %
(adjustable)
(adjustable)
(adjustable)
algorithms)
2000m
PD3
VE.Direct
1,25 kg
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bluesolar mppt 100Bluesolar mppt 300Blue power bluesolar mppt 100/30

Tabla de contenido