c� Setting the height of the heat platen
The pressure applied by the heat platen can be altered to suit operator requirements.
The cold platen can also be fully lowered to leave a gap between the two platens (maxi-
mum distance in the working position: 15mm).
1.
2.
3.
4.
Pressure
adjustment wheel
d� Changing the work platen
There are two placement guides on the underside of the lower platen to place your
hands on and make the platen easier to lift off for changing.
Thumbscrews
www.sefa.fr
Undo the attachment screw.
Turn the pressure adjustment wheel clockwise to lower the heat platen
(and increase the pressing force).
Turn the other way to reduce the pressure.
Tighten the attachment screw to apply the setting.
User guide - SEFA ECLAM V3 Series
Attachment screw
Placement guides
9