6. Once the solenoid is unlatched, flip the toggle switch back to
the middle/neutral position. Again, this will conserve the
Pro48's batteries.
NOTE: The side CHATTER switch should be set to ACTIVATE.
F. Chatter the solenoid valve
NOTE: The GOOD LED must illuminate under the "Solenoid and
Activate mode" before using the chatter mode.
1. To chatter the solenoid for the purpose of locating the valve
from the clock, turn the clock off and switch the Pro48 to OFF
mode.
2. TURN OFF THE WATER to irrigation system.
3. Disconnect both the station and common wire from the
controller.
4. Connect the Pro48 by attaching the red lead to the station wire
and the black lead to the common.
5. Select side switch to CHATTER and top Switch to SOLENOID
mode.
6. Proceed to the field and listen for the chattering sound at the
solenoid valve.
G. Sending Tone and Tracing
The tone function is used for identifying the route and end point of
a wire. For the tone function to be useful, a tone probe like the
Pro210F is required. If you purchased the Pro48 multi-function
irrigation tester separately, a tone probe will need to be purchased
to use this function. To send a tone with the Pro48, follow these
instructions.
1. Connect the red lead to the station wire and the black lead to
earth ground.
2. Place the top switch to the SEND TONE mode.
3. Proceed to opposite end of wire and locate the tone with the
Pro210F tone probe. Reception of the tone is strongest on the
target wire.
5