5.8
Relief the pressure in unconnected hoses and tools
5.8.1
General
Temperature differences can cause overpressure in unconnected hoses and tools. This overpressure
can make it impossible to connect the parts. You can use the pressure relief tool to remove this
overpressure. This accessory is available for all Holmatro hose systems and is supplied by default with
every pump.
NOTICE
We recommend you keep more than one of these tools on hand.
5.8.2
Hose with CORE™ couplers
Refer to Fig. 8.
Hook the pressure relief tool over the male coupler (1).
Turn the knob clockwise (2) to release the pressure. Some oil will be released.
Turn the knob counterclockwise (3).
Remove the pressure relief tool from the coupler (4).
5.8.3
Slangen met dual-koppelingen
Zie Fig. 9.
Druk het drukontlastgereedschap op de mannelijke koppeling (1). De knop zal naar buiten komen
(2).
Wikkel een doek rond het drukontlastgereedschap.
WARNING
Zorg ervoor dat de doek alle olieopeningen bedekt; zonder een doek kan er een wolk olie
ontstaan.
Druk het drukontlastgereedschap krachtig met de knop op de grond of tegen een muur (3) om de
overdruk af te laten. Hierbij komt wat olie vrij.
Verwijder het drukontlastgereedschap van de koppeling (4).
6
Use
6.1
General
The equipment of a rescue system must always be ready for use. That means the equipment must be
checked and inspected directly after use, before it is stored.
WARNING
Make sure you are up to date on all safety regulations and that you have mastered the use of
all equipment of the system you are going to work with.
Never try to connect or disconnect hydraulic couplers if the equipment is being used or if the
system is under pressure.