Descargar Imprimir esta página

Dalla Corte EVOLUTION Manual De Usuario página 35

Ocultar thumbs Ver también para EVOLUTION:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

FLOWMETER GROUP 3
LED of dispensing button being
used blinks. To stop dispensing,
press button P3 of group 3.
To cancel the alarm turn the
main switch of the machine off
and back on. This alarm is trig-
gered when the electronic bo-
ard cannot receive any readings
from flowmeter of group 3 du-
ring coffee dispensing.
FLOWMETER GROUP 4
LED of dispensing button being
used blinks. To stop dispensing,
press button P3 of group 4.
To cancel the alarm turn the
main switch of the machine off
and back on. This alarm is trig-
gered when the electronic bo-
ard cannot receive any readings
from flowmeter of group 4 du-
ring coffee dispensing.
TIMEOUT ON GROUP 1
LED # 3 on group 1 blinks and
machine gives out 1 beep.
To cancel alarm press button P3
of group 1. This alarm is trigge-
red when button P3 of group 1 is
used to make coffee continuou-
sly for over 4 minutes.
TIMEOUT ON GROUP 2
LED # 3 on group 2 blinks and
machine gives out 1 beep.
To cancel alarm press button P3
of group 2. This alarm is trigge-
red when button P3 of group 2 is
used to make coffee continuou-
sly for over 4 minutes.
TIMEOUT ON GROUP 3
LED # 3 on group 3 blinks and
machine gives out 1 beep.
To cancel alarm press button P3
of group 3. This alarm is trigge-
red when button P3 of group 3 is
used to make coffee continuou-
sly for over 4 minutes.
TIMEOUT ON GROUP 4
LED # 3 on group 4 blinks and
machine gives out 1 beep.
To cancel alarm press button P3
of group 4. This alarm is trigge-
red when button P3 of group 4 is
used to make coffee continuou-
sly for over 4 minutes.
35

Hide quick links:

Publicidad

loading