enUS - Instructions for use
For your safety
WARNING
!
You must read and understand these instructions for use
before you use the particulate respirator; and you must
strictly follow these instructions.
Failure to do so could lead to sickness or death.
If you have any questions concerning these instructions or how to
properly use the particulate respirator, ask your supervisor or call
Dräger in the USA (see Approval Label). In other countries, please
contact the respective Dräger subsidiary or your local dealer.
Supervisors have to ensure that in their field of responsibility all
users are familiar with these instructions for use and will use the
particulate respirators in strict accordance with these instructions
for use.
Description
®
1)
The Dräger X-plore
1950
series are particulate respirators with
protection class N95.
The particulate respirators are available in different sizes which are
indicated by "S"and "M/L".
If the designation contains "V", the particulate respirator features
an exhalation valve which facilitates exhalation during use.
Intended use
The particulate respirators are designed to reduce the percentage
of certain solid and liquid airborne particles that a user will inhale
when working in certain environments. The particulate respirators
do NOT eliminate the risk of inhaling airborne particles.
Dräger X-plore 1950 particulate respirators may be used for
airborne solid particles such as from grinding, sanding, sweeping,
sawing or processing minerals; and for liquid particles or
particulate aerosols that do not contain oil.
Dräger X-plore 1950 are NIOSH-rated for 95 % filtration efficiency
against solid and liquid aerosols that do not contain oil ("N95").
In the United States these particulate respirators are intended for
occupational use only.
Approvals
The particulate respirators' performance characteristics - e.g. the
types and percentages of the particles that they filter - fulfill the
National Institute for Occupational Safety and Health ("NIOSH")
standards set forth at 42 CFR, Part 84. For more information see
Approval Label.
Limitations on use
Never use an individual particulate respirator for more than
one single 8-hour work shift.
Replace the particulate respirator as soon as you notice any
difficulty in inhaling.
Never use the particulate respirators in atmospheres
containing less than 19.5 % oxygen, since these particulate
respirators do not supply oxygen.
Never use the particulate respirators in atmospheres
containing oil aerosols.
Do not enter unventilated areas such as containers, shafts or
ducts when wearing one of the mentioned particulate
respirators.
Never use the particulate respirators as protection against
chemical, biological, radioactive, or nuclear (CBRN) warfare
hazards.
Never use a damaged, used, or expired particulate respirator.
Never use the particulate respirators for protection against
inhaling
paint spray
gases
vapors
asbestos particles
sandblasting particles
lead
arsenic
4,4' methylene dianiline (MDA)
cadmium
other contaminants that are unknown or immediately
dangerous to life or health.
Never use the particulate respirators as protection against
radioactive particles and radiation.
Never use the particulate respirators in atmospheres with
contaminant concentrations that exceed 10 times the
Permissible Exposure Limit (PEL), specific OSHA standards,
or other applicable regulations, whichever is lower. For PELs
please refer to OSHA standard 29 CFR 1910.1000.
If specific OSHA or other applicable regulations apply to a
certain substance or application, you must strictly follow these
regulations.
When used to reduce inhalation of silica particles, you must
additionally adhere to all requirements of OSHA regulation 29
CFR 1926.1153 and/or 29 CFR 1910.1053.
General warnings and cautions
A properly selected particulate respirator is essential to protect
your health. Before using this particulate respirator, consult an
Industrial Hygienist or Occupational Safety Professional to
determine the suitability for your intended use.
Before occupational use of this respirator, a written respiratory
protection program must be implemented meeting all the local
government requirements. In the United States, employers
must comply with OSHA 29 CFR 1910.134 which includes
medical evaluation, training, and fit testing.Particulate
respirators that are properly selected and fitted will only reduce
the contaminant concentration.
Do not modify the particulate respirators.
Persons with breathing difficulties, such as asthma or with a
history of heart disease, should consult a physician and
complete a medical evaluation prior to use.
Do not use with beard or facial hair or other conditions that
prevent a good seal between the face and the sealing surface
of the respirator.
®
1)
X-plore
is a registered trademark of Dräger.
Do not share particulate respirators with other people for
hygienic reasons.
The respirators are not designed to be used by children.
Never remove your respirator when you are in contaminated
areas! The outer surface of the respirator must be treated as if
it is contaminated at all times. Wash hands immediately after
removing the respirator.
Use as protection against bacterial or viral
agents and/or Medical use
These particulate respirators have not been cleared in the US
by the FDA for use as surgical masks, in healthcare settings or
for use by the general public in public health medical
emergencies.
In countries which are not subject to these regulations, these
particulate respirators may be used in accordance with the
following notes:
These particulate respirators do not include complete
warning notices or recommendations of use for personnel
in the health sector or other areas where contact with
infectious germs or biologically harmful substances is
possible. Information on this topic is available from the
hygiene officer or Dräger.
The particulate respirators can reduce the amount of
biologically harmful substances (e.g. mold, anthrax
bacteria, tuberculosis bacteria, bird flu, SARS virus, or
other biological or viral agents) in the inhaled air. However,
they cannot preclude the risk of an infection or illness.
Particulate respirators cannot prevent the inhalation of all
harmful particles. Rather, they filter contaminants at the
designated efficiency (for example "N95" designates a
filtration efficiency of 95 %). Inhaling an individual agent
can be dangerous and lead to serious illness. No legal or
official limits have yet been defined for these substances.
The particulate respirators do not prevent an infection by
another route (e.g. contact of contaminated objects with
the mouth, nose or eyes or via contaminated food).
Frequent washing of hands can reduce the risk of
infection, but not eliminate it.
Always observe the recommendations of the responsible
national authorities.
If a particulate respirator has come into contact with
biologically harmful substances, it must be disposed in
accordance
with
the
applicable
regulations.
Only use the particulate respirator once.
The particulate respirators are not intended for use as
surgical masks.
Explanation of symbols on the packaging
Strictly follow the instructions for use!
indicates the temperature range of storage conditions
+55C
-10C
indicates the maximum humidity of storage conditions
<90%
Use and donning
1. Remove the particulate respirator from its packaging.
2. Prior to use, make sure that there are no holes in the breathing
zone and that the particulate respirator is not damaged. Pay
particular attention to the weld of the head strap loops (see
figure B). If the particulate respirator is damaged, use a new
one.
3. Ensure that head and eye protection do not interfere with the
particulate respirator.
4. Unfold the particulate respirator and slightly preform the centre
of the nose clip (see figure A).
5. Hold the mask in one hand and expand the loop on the harness
until the top loop almost lies against the particulate respirator
(see figure B).
6. Hold the particulate respirator under the chin and over the
nose so that the foam rests on the nose (see figure C). Stretch
the bottom loop and pull it over the head to the neck (see figure
C-1). Position the top loop high on the back of the head (see
figure C-2).
7. Adjust the length of the loops (see figure D) so that the
particulate respirator sits comfortably on the head and the
tension is evenly distributed.
8. Adjust the nose clip to the shape of the nose, using both hands
(see figure E). Adjustment using only one hand might impede
the tight fit.
9. To check the seal, cover the particulate respirator with both
hands and, if necessary, seal the exhalation valve (see figure
F). Exhale forcefully.
If air leaks around the nose, readjust the nose clip. If air leaks
at the edges, adjust the particulate respirator and check the fit
of the harness on the head.
WARNING
!
If you cannot achieve satisfactory fit, do NOT enter the
contaminated area. See your supervisor.
Failure to do so could lead to sickness or death.
Duration of use
The number of hours that the particulate respirators may be used
depends on several factors, including the concentration of
contaminants in the air, and the amount of work that the user is
performing. but must in no case exceed 8 hours (see "Limitations
on use").
Leave the work area if dizziness or other signs of distress occur.
Storage and care
Always store the particulate respirators in their original packaging
in a cool, dry room in such a way that they cannot be damaged.
Avoid exposure to direct sunlight. Do not store the particulate
respirators after the indicated expiry date.
Make sure the particulate respirators are clean. Never try to clean
a particulate respirator.
Storage temperature: -4 °F to 104 °F (-20 °C to 40 °C)
Relative humidity: maximum 80 %
Disposal
Used particulate respirators must be disposed of in accordance
with local disposal regulations.
waste
disposal

Publicidad

loading

Resumen de contenidos para Dräger X-plore 1950

  • Página 1  national authorities. Distributor in the USA: Dräger X-plore 1950 are NIOSH-rated for 95 % filtration efficiency If a particulate respirator has come into contact with  against solid and liquid aerosols that do not contain oil ("N95").
  • Página 2 N'essayez jamais de nettoyer un respirateur contre les PAS le risque d'inhaler des particules dans l'air. particules. Les respirateurs contre les particules Dräger X-plore 1950 peuvent La FDA américaine n'a pas autorisé l'utilisation de ces  Température de stockage : -4 °F à 104 °F (-20 °C à 40 °C) être utilisés pour les particules solides dans l'air émises par ex.
  • Página 3 áreas en las que es posible encuentren en el aire. tener contacto con gérmenes infecciosos o sustancias Los respiradores antipartículas Dräger X-plore 1950 pueden biológicas nocivas. Puede solicitarse la información utilizarse como protección contra las partículas sólidas que se correspondiente al responsable de higiene o a Dräger.