Praxair Compact 200H 2R Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1 – Alarm - Thermal surcharge
2 – Machine under voltage indicator
3 – Digital display
4 – Adjustment parameter button
5 – Spot time indicator
6 – 4T (4 times) torch mode indicator
7 – 2T (2 times) torch mode indicator
1 – Alarm – thermal surcharge – When lighted unable machine running by thermal surcharge. The thermal sensor is
placed on the central main transformer coil.
2 – Machine under voltage – Indicates that machine is under input voltage.
3 – Digital display – Shows the selected parameter value. During welding:
- the digital display indicates the value of welding current A - Ampere (on digit versions)
- when the button is rotated the digital display shows the wire motor speed m/min
- after this adjustment automatically turns to indicate the welding current value.
4 – Adjustment button – Adjusts the selected parameter value.
5 – Spot mode – When selected, indicates that machine is at spot welding mode, automatically interrupting the
welding at the end of the selected period.
6 – 4 times mode – When selected indicates that machine is on 4 times torch mode. Under extensive welding seams,
the operator can press and release torch trigger; the machine continues to welding. Press and release button to stop
welding.
7 – 2 times mode – When selected indicates that machine is under 2 times torch mode. To continuous welding torch
trigger must be always pressed.
8 – Mode 2T/4T/Spot welding selecting key button.
9 – Selecting key button – Selects to adjust post-gas, spot, burn-back and up-slope time parameter.
10 – Post-gas – When selected allows adjusting, between 0 and 10 seconds, the gas flow time after stop welding; this
protects the welding seam from oxidation and cools the torch.
11 – Spot time: When selected the welding spot time. After this time the machine automatically stops.
12 – Burn-back – When selected allows adjust, between 0 and 10 seconds by means of the adjusting button, the wire
length at the torch, at the end of welding. The burn-back time can be adjusted between 0,1 and 1 second.
13 – Up-slope motor speed – When selected allows adjust, by means of the adjusting button, the up-slope speed
motor time till reach the selected speed. It must be adjusted between 0,1 and 1 seconds.
14 – Wire speed – When selected allows adjust, by means of the adjusting button, the wire speed between 0 and 18
m/min. This parameter is continuous active; with machine running, it's enough touch the button to adjust wire speed.
6
Welding current
Gas flow
Torch trigger
1st/2nd times
push/release
Welding current
Gas flow
Torch trigger
1st time / push trigger
8 – 2T/4T/Spot selector
9 – Adjustable parameters selector
10 – Post-gas adjustment indicator
11 – Spot time adjustment indicator
12 – Burn-back time adjustment indicator
13 – Up-slope speed motor time adjustment indicator
14 – Wire feed motor speed adjustment indicator
post-
gaz
3rd/4th times
push/release
post-
gaz
2nd time - release trigger
200H 2R

Publicidad

Tabla de contenido
loading

Tabla de contenido