SWB505 MultiMount™ / SWB605 PowerMount™ Weigh Module » Installation
Options for Securing the Weigh Modules
7
»
BOLT
the weigh module:
OR
Bolt top plate
to tank leg
This end only:
Tank Leg
do NOT use washers
for 4400kg / 10'000lb
module
Concrete/Foundation
Mounting plate surface must be level to 1/2° or
All weigh modules must be in the same plane within 3mm (1/8").
Load Cell Connection Guide
8
»
POWER
• Align connectors correctly
• Tighten connectors
• Protect connectors from
mechanical shock
- OR -
LEVEL AND GROUT
OR
Bolt base plate
Bolt top plate
to tank leg
Shim as
Leveling Adjustment Nut
needed
Expansion
Anchor
1mm
(1/16")
100mm (6")
Download Installation Guide:
Installation Guide is available in:
English, German, Spanish, French,
Italian, Dutch, Portuguese, Swedish,
Danish, Norwegian, Polish, Czech,
Hungarian, Russian, Turkish
www.mt.com/ind-downloads-multimount
- OR -
the weigh module:
Tank Leg
Bolt base plate
Nonshrink
Epoxy Grout
Anchor
Concrete/Foundation
Insert
J-Bolt
Installation Tips and Precautions:
• Never cut the load cell's cable or extend its length.
• Avoid moisture and dust.
• Ensure voltage stability – use a regulated power
supply.
• Avoid overload and shock.
• Ensure good grounding.
• For hazardous area installations in Europe, refer to
enclosed instructions (30104376 / 175389R).
Download Installation Guide:
Installation Guide is available in:
English, German, Spanish, French,
Italian, Dutch, Portuguese, Swedish,
Danish, Norwegian, Polish, Czech,
Hungarian, Russian, Turkish
www.mt.com/ind-downloads-powermount
WELD the weigh module:
• Remove load cell from weigh module before welding.
• Ground wire of welder must be as close to the weld
seam as possible to ensure proper grounding.
Contact authorized METTLER TOLEDO technician for
proper removal and re-installation of load cells.
Size 1 weld: 5mm (3/16")
Size 2/3 weld: 9mm (3/8")
25mm (1") long
on 75mm (3") centers
Tank Leg
Contact authorized METTLER TOLEDO service
technician to activate the weigh modules for startup
and calibration.
Contact Information:
www.mt.com/contact
© 2015 Mettler-Toledo, LLC
10/2015 | 61807399 | Rev C