During construction, if the pump is installed before its power cord can be plugged in or direct wired, the power cord must be
protected from the environment to prevent water from wicking through the cord end into the pump housing. If water enters the
pump an electrical short can occur from the pump to its surroundings, which will energize the surroundings.
DO NOT use an extension cord to power the product. Extension cords can overload both the product and extension cord supply
wires. Overloaded wires will get very hot and can catch on fire.
This product requires a separate, properly fused and grounded branch circuit, sized for the voltage and amperage requirements of
the pump, as noted on the nameplate. Overloaded branch circuit wires will get very hot and can catch on fire.
NEVER use this product with or near flammable liquids. If the rotating elements inside this pump strike any foreign object,
sparks may occur. Sparks could ignite flammable liquids.
DO NOT install this product in locations classified as hazardous or in explosive atmospheres as defined by any applicable safety
code.
Keep battery in a well ventilated area, away from sparks and open flames. Batteries generate flammable gasses both charging
and discharging, which can explode or catch fire if ignited.
The pump must be installed in accordance with all applicable codes and ordinances.
DO NOT allow children to play with the pump.
DO NOT allow children, or any person who is unqualified to use the pump. Any person who is unaware of the dangers of this
pump, or whom has not read this manual, can easily be injured by the pump.
Wear adequate PPE when working on pumps or piping that have been exposed to wastewater. Sump and sewage pumps often
handle materials which can transmit illness or disease upon contact with your skin and other tissues.
DO NOT remove any tags or labels from the pump or its cord.
ALWAYS, keep clear of the pump's suction and discharge openings. The rotating elements of this pump are designed to draw
in and pass foreign objects.
NEVER, insert fingers into pump while it is energized. A stopped, energized pump may start without warning, via external test
features built into the control system.
Wear adequate PPE when working with batteries. Batteries contain strong acids that can cause severe burns to skin and soft
tissues, if spilled. Prior to servicing your battery, refer to the battery manufacturers instruction manual or Safety Data Sheet
(SDS) for a listing of proper PPE, proper handling techniques, and proper spill response, to minimize your risk of injury.
DO NOT touch the finned top surface of the charging unit. This surface becomes hot during normal battery charging may burn
exposed skin. Unplug the charger and allow it to cool prior to servicing.
RISK OF ELECTRIC SHOCK - continued

RISK OF FIRE

RISK OF SERIOUS INJURY OR DEATH