EN
Parts Replacement/Maintenance
Chart 1 – Air Cap
ORDER NO. FOR
AIR CAP
703899 (HVLP)
NOTE 1: Guns with HVLP caps must not exceed 0.7 bar (10 psi) air cap pressure with
NOTE 2: When removing air cap from retaining ring, don't remove slip ring (2)
Chart 2 – Fluid Nozzles & Fluid Needles
NO. ON
FLUID NOZZLE
SN-37-11
SN-37-12
SN-37-13
SN-37-14
SN-37-15
NOTE: When replacing the fluid nozzle or fluid needle, replace both at the same time.
www.carlisleft.com
NUMBER
RECOMMENDED
ON CAP
INLET PRESSURE
BAR/PSI
HV20
1.0 – 1.3 bar
14 – 18 psi
gun fully triggered. (Aproximately 24 psi gun inlet pressure.) (See accessories
for air cap test kit which is available to set the exact cap pressure.)
or retaining ring seal (5) from retaining ring. Damage to the parts may
occur. Slip ring and retaining ring seal are not available as replacements.
Simply wipe parts clean and reassemble with new or clean air cap.
TIP SIZE I.D.
NO. ON FLUID NEEDLE
(MM)
(TO MATCH FLUID NOZZLE)
1.1
1.2
1.3
1.4
1.5
Lightly lubricate the threads of the fluid nozzle before reassembling. Torque
to 18–20 Nm (13–15 ft-lbs). Don't over tighten the fluid nozzle. Use 10 mm
wrench supplied with gun.
AIR FLOW
LPM/SCFM
317 – 368 LPM
11.2 – 13.0 SCFM
ORDER NO. FOR
NOZZLE & NEEDLE SET
SN-38-11
702711
SN-38-12
702712
SN-38-13
702713
SN-38-14
702714
SN-38-15
702715
12 / 16