Program Scenes

Scenes are preset lighting levels, fade times, and shade positions stored in the control unit. (Note that AC shades can 
be programmed in a scene as only fully open, fully closed, or unaffected; Sivoia QED
at any preset level or unaffected.) You can program up to 16 scenes, plus OFF (scene 0). Any time a scene button is 
pressed or input from an optional control interface is received, the system activates the desired scene.
Program Scenes 1 through 4 (Save Mode)
If the control unit is set to the factory default Sd save mode (adjustments to zone settings are saved for the current 
scene), you can program scenes 1 through 4 without entering setup mode.
NOTE: To program scenes using setup mode, refer to page 21. To select a save mode, refer to page 22.
Set the scene settings for each zone
2
ZONE 5
ZONE 6
LED Displays for Programming Scene Settings
Lighting Zones
Off 
On 50% 
On 100% 
Unaffected 
Legend:
LED lit
LED off
18     GRAFIK Eye
 4000 Series Control Unit Installer's Guide 
®
FADE
TEMPORARY
ZONE
ZONES
M S
MASTER
Select a 
scene
1
Scene 1
Scene 2
Scene 3
Scene 4
OFF
AC Shade Zones
Fully open 
Fully closed 
Unaffected 
To program scenes 1 through 4 using save mode:
1. Select a scene. Press the SCENE button for the scene you 
want to program.
2. Set the scene settings for each zone.
  For lighting zones, press the ZONE 5 or 6 button to set 
the right visual intensity for this scene.
  For AC shade zones, press the ZONE 5 or 5 button 
until the ZONE LEDs match the right shade position for this 
scene. See the illustration below.
  For Sivoia QED shade zones, press the ZONE 5 or 6 
button until the ZONE LEDs match the right shade position 
for this scene. See the illustration below.
NOTE: To quickly set a shade zone to fully open or fully 
closed, press and hold the ZONE 5 or 6 button for about 
three seconds.
  For unaffected zones, press and hold the ZONE 6 
button until all its LEDs go out and the middle three LEDs 
light (this may take up to 10 seconds). This zone's settings 
will not be affected when this scene is selected.
To reprogram an unaffected zone as affected, follow 
the steps above. Then press the ZONE 5 button for about 
three seconds until the middle three ZONE LEDs are no 
longer lit. Program the zone's settings.
Sivoia QED Shade Zones
Fully open 
Fully closed 
Unaffected
 shades can be programmed 
TM
Preset 1
Preset 2
Preset 3